Test No. FV32 is a tapered membrane problem with irregular mesh. The geometry and mesh symmetry are maintained along the x-direction. The shear behavior of membrane elements in the normal modes analysis is examined using OptiStruct.
The 4-node quad elements with 16x8 mesh configuration are used in test FV32. The displacements in z direction are fixed on all nodes and the x- and y-translation displacements are fixed for the nodes along the y-axis. The material properties for the membrane are:
E = 200x109 N/m2, = 0.3 and = 8000 kg/m3
The frequency of each targeted mode is normalized with the closed form solution.
f* = closed form solution
Mode 1 |
Mode 2 |
Mode 3 |
|||
f* |
44.623 Hz |
f* |
130.03 Hz |
f* |
162.70 Hz |
|
|||||
Mode 4 |
Mode 5 |
Mode 6 |
|||
f* |
246.05 Hz |
f* |
379.90 Hz |
f* |
391.44 Hz |
<install_directory>/demos/hwsolvers/optistruct/fv32.fem
NAFEMS Ltd, The Standard NAFEMS BENCHMARKS TNSB Rev. 3, NAFEMS Ltd, Scottish Enterprise Technology Park, Whitworth Building, East Kilbride, Glasgow, United Kingdom, 1990.