HyperWorks Solvers

/GAUGE

/GAUGE

Previous topic Next topic Expand/collapse all hidden text  

/GAUGE

Previous topic Next topic JavaScript is required for expanding text JavaScript is required for the print function  

Block Format Keyword

/GAUGE - Gauges

Description

Defines gauges.

Format

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

/GAUGE/gauge_ID/unit_ID

gauge_title

node_ID

 

 

 

 

shell_ID

DIST

 

 

hmtoggle_plus1Flag Definition

Field

Contents

SI Unit Example

gauge_ID

Gauge identifier

(Integer, maximum 10 digits)

 

unit_ID

Optional unit identifier

(Integer, maximum 10 digits)

 

gauge_title

Gauge title

(Character, maximum 100 characters)

 

node_ID

Node identifier

(Integer)

 

shell_ID

Shell identifier

(Integer)

 

DIST

Distance between gauge and shell surface

Default = 0  (Real)

> 0: gauge in the side pointed by normal of shell surface

< 0: gauge in the opposite side of the normal of shell surface

symbol_m

hmtoggle_plus1Comments
1.Pressure gauges can be defined by:
A node using a node identifier (node_ID > 0), or
A shell element (shell_ID) and a distance (DIST). In this case node_ID must be equal to 0
2.Pressure gauges have a few restrictions:
Only 4-node shells can be used for shell_ID
For Coupled Euler Lagrange interface only - shells (shell_ID) must be used with a distance (DIST) greater than interface type 18 gap
For Finite Volume Method only - nodes (node_ID) must be used