/IMPL/AUTOSPC - Constraining Automatically Zero Stiffness Degrees-of-Freedom
Description
A zero stiffness DOF will be constrained automatically.
Format
/IMPL/AUTOSPC/Keyword3
Data |
Description |
Keyword3 |
= ON (Default): Node will be constrained in translational or rotational DOF, only if zero stiffness is true in all directions. = OFF: Deactivation flag = ALL: Constrains any DOF of zero stiffness. |
1. | /IMPL/AUTOSPC/ALL could lead to an over-constrained structure, especially for geometric nonlinear analysis, where using Quasi-static is the better choice. |
See Also: