Engine Keyword

/IMPL/SBCS/MSGLV - Specifies Message Level for BCS (Boeing) Solver

Description

Describes the message level for BCS (Boeing) solver.

Format

/IMPL/SBCS/MSGLV/n

Data

Description

n

= 0: no printed messages, except the primary messages generated by standard error handler (default value).

= 1: produces a small amount of runtime statistics and any detailed error messages.

= 2: creates a more complete set of runtime statistics and a log of steps in the process.

= 3: produces diagnostic output, including output of the content of various arrays whose length is no larger than the number of equations.

> 4: will produce volumes of output for debugging purposes.

Comments

1.A setting greater than 2, produces debugging output and is not recommended for general use.