HyperWorks Solvers

/MONVOL/PRES

/MONVOL/PRES

Previous topic Next topic Expand/collapse all hidden text  

/MONVOL/PRES

Previous topic Next topic JavaScript is required for expanding text JavaScript is required for the print function  

Block Format Keyword

/MONVOL/PRES - Pressure Load Curve

Description

Describes the pressure load curve monitored volume type.

Format

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

/MONVOL/PRES/monvol_ID/unit_ID

monvol_title

surf_IDex

 

 

 

 

 

 

 

 

 

Ascalet

 

 

 

 

fct_ID

Fscale

 

Itypfun

 

 

 

 

 

hmtoggle_plus1Flag Definition

Field

Contents

SI Unit Example

monvol_ID

Monitored volume identifier

(Integer, maximum 10 digits)

 

unit_ID

Optional unit identifier

(Integer, maximum 10 digits)

 

monvol_title

Monitored volume title

(Character, maximum 100 characters)

 

surf_IDex

External surface identifier

(Integer)

 

Ascalet

Abscissa scale factor for time based functions

(Real)

fct_ID

Load curve identifier for or dp(t)

(Integer)

 

Fscale

Load curve scale factor

Default = 1.0  (Real)

Itypfun

Argument of the pressure function flag.

(Integer)

=0: pressure depends on relative volume

=1: pressure depends on time

 

hmtoggle_plus1Comments
1.surf_IDex must be defined using segments associated with 4-nodes or 3-nodes shell elements (possibly void elements), and not with /SURF/SEG.
2.The volume must be closed and the normals must be oriented outwards.
3.Abscissa scale factors are used to transform abscissa units in airbag functions, for example:

where, t is the time.

where, P is the pressure.