AUTOSPC
|
<YES, NO>
Default = YES
|
If YES, the global stiffness matrix is checked for degrees-of-freedom (DOF) with no stiffness. If found, these DOF are automatically constrained.
If NO, the DOF with no stiffness are not automatically constrained.
Note:
1. | PARAM, AUTOSPC is generally applicable only to grid points (with unconstrained DOF) attached to structural elements. |
2. | Rotational DOF of grid points that are connected only to solid elements are automatically constrained in the pre-processor and are not affected by PARAM, AUTOSPC. |
3. | Free grid points are also automatically constrained in the pre-processor and are not affected by PARAM, AUTOSPC. |
4. | The list of grids with degrees of freedom that were constrained by the second round of AUTOSPC is output to the .HM.comp.cmf file. |
|