HyperWorks Solvers

PARAM, CONTFEL

PARAM, CONTFEL

Previous topic Next topic No expanding text in this topic  

PARAM, CONTFEL

Previous topic Next topic JavaScript is required for expanding text JavaScript is required for the print function  

Parameter

Values

Description

CONTFEL

<YES, NO, or AUTO>

Default = AUTO

Defaults:

1.The default is AUTO when the parameter is not present in the deck.
2.This parameter cannot be specified in the input deck without a value. OptiStruct will error out in this case.

If YES, Contact-friendly elements are activated.

If NO, Contact-friendly elements are not activated.

If AUTO, Contact-friendly elements are activated for second-order Solid or Gasket elements in Node-to-Surface (N2S) contact.

Note: