Importing Solver Options
Click Select Options, located next to Solver options, to open a dialog with the different options available. The contents of the dialog varies according to the user profile you have selected.
Generic material Import a model in the generic material mode, in which all material sub-options, parameters, and data lines are supported as simple text. Expand loads on sets All loads on sets are expanded to individual nodes/elements. Expand sets defined by range Imports all sets with the GENERATE parameter as regular sets. This is useful when node/element IDs are renumbered during import. Import Id'sRetains any pre-existing entity IDs during import.Organize orphan systems, vectors, beamsects into separate collectorsOrganizes orphan systems, vectors, and beamsections into a separate collector during import.When selected, system collectors defined via HMNAME will be honored, and systems organization into particular System Collectors based on their position in the deck will be honored.An Orphaned system is a system in a master or include file that exists without a HMNAME System Collector in the same include file. Upon import, Orphaned systems are organized into auto generated System Collectors that reside on the same include files as the Orphaned systems. The solver import option Organize unidentified systems into separate collectors controls how the Orphaned systems are organized into the auto generated System Collector(s). When this check box is cleared (default), a single System Collector is created and all Orphaned systems are organized into that single System Collector. When this check box is selected, separate System Collectors are created for each Orphaned system. If a property is assigned to the component, then the ID will be stored in the component. In case of indirect assignment the ID will be stored in the property, and in case of another entity the ID will be taken from the corresponding entity.
|
Read *INITIAL_STRESS_SHELL and *INITIAL_STRAIN_SHELLThese options determine whether to read the *INITIAL_STRESS_SHELL and *INITIAL_STRAIN_SHELL keywords from the solver deck before importing in HyperMesh. By default, both of these check boxes are selected, which results in HyperMesh automatically reading the keywords. If you clear these check boxes, then the data from the *INITIAL_STRESS_SHELL and *INITIAL_STRAIN_SHELL keywords will be exported to a .hmx file. Map LSDYNA Titles / Headings to HM namesHyperMesh maintains only one name for every solver keyword entity mapped to HyperMesh named entities. This option allows you to choose between the HyperMesh names (if present) in the solver deck as a comment and name present in the LS-DYNA keyword. By default this option is off indicating the preference to the HyperMesh name. Include Type This option is only available if the Import as Include option is activated in the Import browser. This option allows you to choose the solver type for the file that you plan to attach as an include to the model loaded in HyperMesh. The following include types are available to choose from in LS-DYNA:
Skip include file in *INCLUDE_STAMP The include file that is referred using the keyword *INCLUDE_STAMPED_PART or *INCLUDE_STAMPED_PART_SET will be skipped upon import when this option is activated. By default, this option is activated. Create HM assembly based on includes This option allows HyperMesh to automatically create assemblies with the name of the include, and the components contained in the include file. The assembly hierarchy data structure also follows the include hierarchy data structure. By default, this option is turned Off. Activate Transformations All of the transformations defined in the model are activated upon import when this option is activated. By default, this option is activated. ConstrainedExtraNodes_PID_NID The keywords *CONSTRAINED_EXTRA_NODE_SET, are associated with the name Xtranodes_PID_NID; where PID is the ID of the *PART keyword and NID is the ID of the Node set ID referenced in this keyword. By default, this option is off. Extend Element Property Offset Select this check box to add an ID offset to elements and properties that do not have solver IDs. Generate Element Property ID's Per Include Select this check box to assign a max ID per Include file, instead of assigning a global max ID to elements and properties that do not have solver IDs. Organize orphan systems, vectors, beamsects into separate collectorsOrganizes orphan systems, vectors, and beamsections into a separate collector during import.When selected, system collectors defined via HMNAME will be honored, and systems organization into particular System Collectors based on their position in the deck will be honored.An Orphaned system is a system in a master or include file that exists without a HMNAME System Collector in the same include file. Upon import, Orphaned systems are organized into auto generated System Collectors that reside on the same include files as the Orphaned systems. The solver import option Organize unidentified systems into separate collectors controls how the Orphaned systems are organized into the auto generated System Collector(s). When this check box is cleared (default), a single System Collector is created and all Orphaned systems are organized into that single System Collector. When this check box is selected, separate System Collectors are created for each Orphaned system.
|
Element to property ratio This affects how imported elements are organized into components. When importing an FE model and the By HM Comment option is selected but no HyperMesh comment cards exist, Nastran users can specify a ratio to be considered when importing HyperMesh entities. On import, HyperMesh will calculate the ratio of the number of elements to the number of properties:
Delete duplicate nodes Select this option to delete duplicate node IDs on import; only the final imported node of a given ID will be retained. Delete duplicate systems Select this option to delete duplicate systems IDs on import; only the final imported systems of a given ID will be retained. Import comment lines on nodes and elements Select this option to enable HyperMesh to read and store Nastran comment lines above nodes and elements. Reading in models with a large number of comments on nodes and/or elements may increase model import time. By default, this option is turned OFF. Organize orphan systems, vectors, beamsects into separate collectorsOrganizes orphan systems, vectors, and beamsections into a separate collector during import.When selected, system collectors defined via HMNAME will be honored, and systems organization into particular System Collectors based on their position in the deck will be honored.An Orphaned system is a system in a master or include file that exists without a HMNAME System Collector in the same include file. Upon import, Orphaned systems are organized into auto generated System Collectors that reside on the same include files as the Orphaned systems. The solver import option Organize unidentified systems into separate collectors controls how the Orphaned systems are organized into the auto generated System Collector(s). When this check box is cleared (default), a single System Collector is created and all Orphaned systems are organized into that single System Collector. When this check box is selected, separate System Collectors are created for each Orphaned system. Read ANSA Comments and Read PATRAN CommentsEnables ANSA and PATRAN comments to be read during import.
|
Element to property ratio This affects how imported elements are organized into components. When importing an FE model and the By HM Comment option is selected but no HyperMesh comment cards exist, OptiStruct users can specify a ratio to be considered when importing HyperMesh entities. On import, HyperMesh will calculate the ratio of the number of elements to the number of properties:
Delete duplicate nodes Select this option to delete duplicate node IDs on import; only the final imported node of a given ID will be retained. Delete duplicate systems Select this option to delete duplicate system IDs on import; only the final imported systems of a given ID will be retained. Import comment lines on nodes and elements Select this option to enable HyperMesh to read and store Nastran comment lines above nodes and elements. Reading in models with a large number of comments on nodes and/or elements may increase model import time. By default, this option is turned OFF. Organize orphan systems, vectors, beamsects into separate collectorsOrganizes orphan systems, vectors, and beamsections into a separate collector during import.When selected, system collectors defined via HMNAME will be honored, and systems organization into particular System Collectors based on their position in the deck will be honored.An Orphaned system is a system in a master or include file that exists without a HMNAME System Collector in the same include file. Upon import, Orphaned systems are organized into auto generated System Collectors that reside on the same include files as the Orphaned systems. The solver import option Organize unidentified systems into separate collectors controls how the Orphaned systems are organized into the auto generated System Collector(s). When this check box is cleared (default), a single System Collector is created and all Orphaned systems are organized into that single System Collector. When this check box is selected, separate System Collectors are created for each Orphaned system.
|
Read Engine Enables you to read the RADIOSS engine cards if an engine file (_0001.rad) is available with the imported input deck. Read INITIAL SHELL Data Enables the reading and import process of RADIOSS initial state cards of 2D elements. Activate transformations Enables the treatment of RADIOSS transformations during the import process, so that transformed entities will be displayed in their transformed position after importing the model. Read INITIAL Brick Data Enables the reading and import process of RADIOSS initial state cards of 3D elements. Organize orphan systems, vectors, beamsects into separate collectorsOrganizes orphan systems, vectors, and beamsections into a separate collector during import.When selected, system collectors defined via HMNAME will be honored, and systems organization into particular System Collectors based on their position in the deck will be honored.An Orphaned system is a system in a master or include file that exists without a HMNAME System Collector in the same include file. Upon import, Orphaned systems are organized into auto generated System Collectors that reside on the same include files as the Orphaned systems. The solver import option Organize unidentified systems into separate collectors controls how the Orphaned systems are organized into the auto generated System Collector(s). When this check box is cleared (default), a single System Collector is created and all Orphaned systems are organized into that single System Collector. When this check box is selected, separate System Collectors are created for each Orphaned system. Create single collector for rigids rbe3 and admass elements When enabled, one component is created for all rigid bodies and one component is created for all admas elements. When disabled, each rigid body and admas element will be read as a single component. |
See Also:
To Import an FE Model into HyperMesh