HyperGraph

Multiple Sample Analysis - Loads MSA - Display Tab

Multiple Sample Analysis - Loads MSA - Display Tab

Previous topic Next topic No expanding text in this topic  

Multiple Sample Analysis - Loads MSA - Display Tab

Previous topic Next topic JavaScript is required for expanding text JavaScript is required for the print function  

On the Display tab, the Run Info sub-tab allows you to plot responses for runs with highest and lowest responses for a particular frequency or a range of frequencies.  It is also possible to review randomized values used for the variables in a particular run.  The Parameter Effects sub-tab allows you to plot sensitive parameters contributing to the response scatter at a particular frequency.  To activate this tab, you must first load a file from the Load tab.

nvh_mult_samp_analysis_loadmsa_display

NVH-Utilities Browser - Display tab (Loads MSA)

Option

Description

Run Info

Allows you to visualize the highest and lowest responses. Also allows you to review the parameter values used in a specific run.


Frequency Selection

Select an option to choose the specific frequency or frequency range.


Specific frequency

Enter a specific frequency or use the slider bar to select a frequency value.


Frequency Range

Frequency range indicates the available range, based on your results PCH file.

Using the From and To fields, you can customize your own frequency band.


Show highest runs

Select the number of runs with the highest responses that you want to view.


Show lowest runs

Select the number of runs with the lowest responses that you want to view.


Display Options

The Display Options dialog allows you to customize the plot, including the scale, weighting, and the plot layout.


Display

Click Display to display the response plots for the chosen number of highest/lowest runs.


Run Directory

Select the directory with the Multiple Sample Analysis runs.


Run Number

Click the response curve and the corresponding run number is listed.  It is also possible to enter the run number manually.


Contributors

Review the randomized parameter value(s) used in theselected HyperStudy run.

Parameter Effects

This allows you to plot sensitive parameters contributing to the response scatter for a selected frequency.

 

Bar

Allows you to plot Anova charts for sensitive parameters at a selected frequency.

Enter a specific frequency in the Specific Frequency field, or use the slider bar to select a frequency value.  When you use the slider bar to select a frequency, a red line is displayed on the response plot and is dragged simultaneously as you drag the slider bar.

 

3D Bar

Allows you to plot 3D bars for a sensitive parameter for a frequency range.