HyperMesh and BatchMesher

Abaqus to Nastran Conversion

Abaqus to Nastran Conversion

Previous topic Next topic No expanding text in this topic  

Abaqus to Nastran Conversion

Previous topic Next topic JavaScript is required for expanding text JavaScript is required for the print function  

The Abaqus to Nastran conversion tool uses an open conversion scheme; you can specify different mappings in the configuration file. Care has to be taken so that the element and property mappings are consistent. A valid mapping scheme is provided in the ConfigurationFile.txt file. This document explains the scope and limitations of the mapping scheme.

 

Elements


HyperMesh elements have two basic attributes – configuration (or config) and type. The "config" defines the basic geometrical shape of an element. For example, tria3 configuration is a 3 node triangular element and hexa8 is an 8-node hexahedral element. The "type" defines the solver specific element type of a particular configuration. For example, the 4-node quadrilateral (quad4) element in Abaqus can be any of the following types: S4, S4R, M3D4, R3D4 and so on. The Element Types panel shows all supported element configurations and their types for a user profile.

For a specific configuration, you can map any supported Abaqus element type to any supported Nastran element type, or vice versa. For example, for an Abaqus to Nastran direction, several 2-noded element configurations such as spring, rigid, bar2, rid, and so on are supported. Because all of them are 2-noded elements, conversion across these configurations is also allowed for some element types. For example, CBUSH is of "spring" configuration in the Nastran user profile and CONN3D2 is of "rod" configuration in the Abaqus user profile. It is possible to map a CBUSH to CONN3D2 even though their configurations are different. The element mapping scheme must be under the *ElemTypeConversion block in the ConfigurationFile.txt file. You need to provide both configuration and type information to specify the element mapping scheme as shown for the Abaqus to Nastran direction below:

HM configuration

Abaqus type

Nastran type

Mass

MASS

CONM2

ROTARYI

CONM2

SPRING1

CELAS1, CELAS2, CBUSH

DASHPOT1

CDAMP1

CONN3D2

CBUSH

CONN2D2

CBUSH

rigid

BEAM

RBE2

LINK

RBE2

PIN

RBE2

TIE

RBE2

KINCOUP

RBE2

COUP_KIN

RBE2

COUP_DIS

RBE2

RB3D2

RBE2

R2D2

RBE2

RAX2

RBE2

RB2D2

RBE2

rbe3

DCOUP3D

RBE3

COUP_DIS

RBE3

DCOUP2D

RBE3

rigidlink

KINCOUP

RBE2

RB3D2

RBE2

BEAM

RBE2

LINK

RBE2

PIN

RBE2

TIE

RBE2

COUP_KIN

RBE2

COUP_DIS

RBE3

R2D2

RBE2

RAX2

RBE2

RB2D2

RBE2

spring

SPRING2

CELAS1,CBUSH

SPRINGA

CBUSH

DASHPOT2

CDAMP1, CBUSH

DASHPOTA

CBUSH

JOINTC

CBUSH

bar2

B31

CBAR,CBEAM

B31H

CBAR,CBEAM

B33

CBAR,CBEAM

B33H

CBAR,CBEAM

B31OS

CBAR,CBEAM

B31OSH

CBAR,CBEAM

PIPE31

CBAR,CBEAM

PIPE31H

CBAR,CBEAM

ELBOW31

CBAR,CBEAM

ELBOW31B

CBAR,CBEAM

ELBOW31C

CBAR,CBEAM

AC1D2

CBAR,CBEAM

GK3D2

CBAR,CBEAM

GK3D2N

CBAR,CBEAM

SAX1

CBAR,CBEAM

B21

CBAR,CBEAM

B21H

CBAR,CBEAM

B23

CBAR,CBEAM

B23H

CBAR,CBEAM

PIPE21

CBAR,CBEAM

PIPE21H

CBAR,CBEAM

F2D2

CBAR,CBEAM

FAX2

CBAR,CBEAM

bar3

B32

CBAR,CBEAM

B32H

CBAR,CBEAM

B32OS

CBAR,CBEAM

B32OSH

CBAR,CBEAM

PIPE32

CBAR,CBEAM

PIPE32H

CBAR,CBEAM

ELBOW32

CBAR,CBEAM

AC1D3

CBAR,CBEAM

MGAX2

CBAR,CBEAM

SFMAX2

CBAR,CBEAM

SFMGAX2

CBAR,CBEAM

SAX2

CBAR,CBEAM

B22

CBAR,CBEAM

B22H

CBAR,CBEAM

PIPE22

CBAR,CBEAM

PIPE22H

CBAR,CBEAM

rod

T3D2

CROD

T3D2H

CROD

T3D2T

CROD

T3D2E

CROD

MGAX1

CROD

SFMAX1

CROD

SFMGAX1

CROD

CONN3D2

CBUSH

T2D2

CROD

T2D2H

CROD

T2D2T

CROD

T2D2E

CROD

GK2D2

CROD

GK2D2N

CROD

CONN2D2

spring CELAS1,CELAS2,CBUSH

gap

GAPUNI

CGAP

GAPCYL

CGAP

GAPSPHER

CGAP

tria3

S3

CTRIA3,CTRIAR

S3R

CTRIA3,CTRIAR

STRI3

CTRIA3,CTRIAR

M3D3

CTRIA3,CTRIAR

SFM3D3

CTRIA3,CTRIAR

R3D3

CTRIA3,CTRIAR

DS3

CTRIA3,CTRIAR

CPE3

CTRIA3,CTRIAR

CPE3H

CTRIA3,CTRIAR

CPE3E

CTRIA3,CTRIAR

CPS3

CTRIA3,CTRIAR

CPS3E

CTRIA3,CTRIAR

CAX3

CTRIA3,CTRIAR

CAX3H

CTRIA3,CTRIAR

CAX3E

CTRIA3,CTRIAR

CGAX3

CTRIA3,CTRIAR

CGAX3H

CTRIA3,CTRIAR

AC2D3

CTRIA3,CTRIAR

ACAX3

CTRIA3,CTRIAR

DCAX3

CTRIA3,CTRIAR

DCAX3E

CTRIA3,CTRIAR

DC2D3

CTRIA3,CTRIAR

DC2D3E

CTRIA3,CTRIAR

quad4

S4

CQUAD4,CQUADR

S4R

CQUAD4,CQUADR

S4R5

CQUAD4,CQUADR

M3D4

CQUAD4,CQUADR

M3D4R

CQUAD4,CQUADR

SFM3D4

CQUAD4,CQUADR

SFM3D4R

CQUAD4,CQUADR

R3D4

CQUAD4,CQUADR

DS4

CQUAD4,CQUADR

GK3D4L

CQUAD4,CQUADR

GK3D4LN

CQUAD4,CQUADR

F3D4

CQUAD4,CQUADR

CPE4I

CQUAD4,CQUADR

CPE4

CQUAD4,CQUADR

CPE4H

CQUAD4,CQUADR

CPE4IH

CQUAD4,CQUADR

CPE4R

CQUAD4,CQUADR

CPE4RH

CQUAD4,CQUADR

CPE4T

CQUAD4,CQUADR

CPE4HT

CQUAD4,CQUADR

CPE4E

CQUAD4,CQUADR

CPS4

CQUAD4,CQUADR

CPS4I

CQUAD4,CQUADR

CPS4R

CQUAD4,CQUADR

CPS4T

CQUAD4,CQUADR

CPS4E

CQUAD4,CQUADR

CAX4

CQUAD4,CQUADR

CAX4H

CQUAD4,CQUADR

CAX4I

CQUAD4,CQUADR

CAX4IH

CQUAD4,CQUADR

CAX4R

CQUAD4,CQUADR

CAX4RH

CQUAD4,CQUADR

CAX4T

CQUAD4,CQUADR

CAX4HT

CQUAD4,CQUADR

CAX4E

CQUAD4,CQUADR

CAXA4N

CQUAD4,CQUADR

CAXA4HN

CQUAD4,CQUADR

CAXA4RN

CQUAD4,CQUADR

CAXA4RHN

CQUAD4,CQUADR

CGAX4

CQUAD4,CQUADR

CGAX4H

CQUAD4,CQUADR

CGAX4R

CQUAD4,CQUADR

CGAX4RH

CQUAD4,CQUADR

AC2D4

CQUAD4,CQUADR

ACAX4

CQUAD4,CQUADR

DC2D4

CQUAD4,CQUADR

DC2D4E

CQUAD4,CQUADR

DCAX4

CQUAD4,CQUADR

DCAX4E

CQUAD4,CQUADR

DCCAX4

CQUAD4,CQUADR

DCCAX4D

CQUAD4,CQUADR

GKPS4

CQUAD4,CQUADR

GKPE4

CQUAD4,CQUADR

GKPS4N

CQUAD4,CQUADR

tria6

STRI65

CTRIA6

M3D6

CTRIA6

SFM3D6

CTRIA6

DS6

CTRIA6

CPE6

CTRIA6

CPE6H

CTRIA6

CPE6M

CTRIA6

CPE6MH

CTRIA6

CPS6

CTRIA6

CPS6M

CTRIA6

AC2D6

CTRIA6

ACAX6

CTRIA6

DCAX6

CTRIA6

DC2D6

CTRIA6

DCAX6E

CTRIA6

DC2D6E

CTRIA6

CAX6

CTRIA6

CAX6H

CTRIA6

CAX6M

CTRIA6

CAX6MH

CTRIA6

CGAX6

CTRIA6

CGAX6H

CTRIA6

quad8

S8R

CQUAD8

S8R5

CQUAD8

S8RT

CQUAD8

M3D8

CQUAD8

M3D8R

CQUAD8

SFM3D8

CQUAD8

SFM3D8R

CQUAD8

DS8

CQUAD8

CPE8

CQUAD8

CPE8H

CQUAD8

CPE8R

CQUAD8

CPE8RH

CQUAD8

CPS8

CQUAD8

CPS8R

CQUAD8

AC2D8

CQUAD8

ACAX8

CQUAD8

DC2D8

CQUAD8

DCAX8

CQUAD8

DCAX8E

CQUAD8

DC2D8E

CQUAD8

CAX8

CQUAD8

CAX8H

CQUAD8

CAX8HT

CQUAD8

CAX8R

CQUAD8

CAX8RH

CQUAD8

CAX8RHT

CQUAD8

CAX8RT

CQUAD8

CGAX8

CQUAD8

CGAX8H

CQUAD8

CGAX8R

CQUAD8

CGAX8RH

CQUAD8

CAXA8N

CQUAD8

CAXA8HN

CQUAD8

CAXA8PN

CQUAD8

CAXA8RN

CQUAD8

CAXA8RHN

CQUAD8

CAXA8RPN

CQUAD8

tetra4

C3D4

CTETRA

C3D4H

CTETRA

C3D4E

CTETRA

AC3D4

CTETRA

DC3D4

CTETRA

DC3D4E

CTETRA

penta6

C3D6

CPENTA

C3D6H

CPENTA

C3D6E

CPENTA

AC3D6

CPENTA

GK3D6

CPENTA

GK3D6N

CPENTA

SC6R

CPENTA

COH3D6

CPENTA

hex8

C3D8I

CHEXA

C3D8

CHEXA

C3D8T

CHEXA

C3D8H

CHEXA

C3D8HT

CHEXA

C3D8IH

CHEXA

C3D8R

CHEXA

C3D8RH

CHEXA

C3D8E

CHEXA

AC3D8

CHEXA

DC3D8

CHEXA

DC3D8E

CHEXA

DCC3D8

CHEXA

DCC3D8D

CHEXA

SC8R

CHEXA

COH3D8

CHEXA

tetra10

C3D10

DC3D10

C3D10H

DC3D11

C3D10M

DC3D12

C3D10MH

DC3D13

C3D10E

DC3D14

DC3D10E

DC3D15

AC3D10

DC3D16

DC3D10

DC3D17

penta15

C3D15

CPENTA

C3D15H

CPENTA

C3D15E

CPENTA

AC3D15

CPENTA

DC3D15

CPENTA

DC3D15E

CPENTA

hex20

C3D20

CHEXA

C3D20H

CHEXA

C3D20R

CHEXA

C3D20RH

CHEXA

C3D20E

CHEXA

C3D20RE

CHEXA

C3D20T

CHEXA

C3D20HT

CHEXA

C3D20RT

CHEXA

C3D20RHT

CHEXA

DC3D20

CHEXA

AC3D20

CHEXA

DC3D20E

CHEXA

Abaqus CONN3D2 connector elements are converted to Nastran CBUSH, PBUSH using the following guidelines:

Connector1 types converted:
oAXIAL: Active = [1], Rigid = [-]
oCARTESIAN, PROJECTION CARTESIAN: Active = [123], Rigid = [-]
oJOIN: Active = [-], Rigid = [123]
oRADIAL-THRUST: Active = [13]*, Rigid = [-]
*Requires cylindrical system
oSLIDE-PLANE: Active = [23], Rigid = [1]
oSLOT: Active = [1], Rigid = [23]
Connector2 types converted:
oALIGN: Active = [-], Rigid = [456]
oCARDAN, EULER, ROTATION, FLEXION-TORSION, PROJECTION FLEXION-TORSION: Active = [456], Rigid = [-]
oREVOLUTE: Active = [4], Rigid = [56]
Special assembled Connector1 types:
oBEAM, WELD = (JOIN + ALIGN): Active = [-], Rigid = [123456]
oCYLINDRICAL = (SLOT + REVOLUTE): Active = [14], Rigid = [2356]
oHINGE = (JOIN + REVOLUTE): Active = [4], Rigid = [12356]
oPLANAR = (SLIDE-PLANE + REVOLUTE): Active = [234], Rigid = [156]
oTRANSLATOR = (SLOT + ALIGN): Active = [1], Rigid = [23456]
oBUSHING = (PROJECTION CARTESIAN + PROJECTION FLEXION-TORSION): Active = [123456], Rigid = [-]
PBUSH stiffness and damping values (Ki, Bi) for active DOFs are mapped from *CONNECTOR BEHAVIOR material data. Rigid DOFs map to RIGID option inside PBUSH.
CBUSH orientation is mapped from *CONNECTOR SECTION Orientation system.
oOnly 1 Orientation system can be mapped to CBUSH CID.
oIf 2 Orientation systems are present in the Abaqus card, HyperMesh only maps the first one.

 

It is also possible to use a simplified conversion of Abaqus connectors (CONN3D2) to rbe2 elements when modifying the ConfigurationFile.txt file. Change the entry for rod element type configuration to:

         rod,CONN3D2 rigid,rbe2

CONN3D2 elements will now be converted to RBE2 elements. Depending on the connection type set in the CONNECTOR SECTION (such as AXIAL or HINGE), degrees of freedom will be set for the RBE2 element. If systems are associated to the connector elemental nodes they will be assigned to the nodes of the RBE2 as well. Not all connection types are supported. If a system is ignored by a particular CONNECTOR SECTION, it will not be assigned to the nodes of the RBE2 either.

These connector types are currently considered in conversion: AXIAL, JOIN, LINK, SLIDE-PLANE, SLOT, ALIGN, REVOLUTE, BEAM, CYLINDRICAL, HINGE, PLANAR, TRANSLATOR, WELD.

*COUPLING/*KINEMATIC constraints with element based surfaces (currently mapped to groups in HyperMesh) are converted into RBE2 rigid elements. *COUPLING/*DISTRIBUTING constraints are converted to RBE3 elements.

All SPRING and DASHPOT related conversions (including JOINTC) map to CELAS1, CDAMP1, or CBUSH/PBUSH using the following guidelines:

SPRING1/2 without ORIENTATION converts to CELAS1
SPRINGA or SPRING1/2 with ORIENTATION converts to CBUSH/PBUSH/PBUSHT with K/KN lines. For SPRING1/2, ORIENTATION maps to CBUSH, CID.
DASHPOT1/2 without ORIENTATION converts to CDAMP1
DASHPOTA or DASHPOT1/2 with ORIENTATION converts to CBUSH/PBUSH/PBUSHT with B line. For DASHPOT1/2, ORIENTATION maps to CBUSH, CID.

 

Sectional Properties


The table below shows supported sectional property mapping between Abaqus and Nastran. Some of the properties in one solver can be converted to two different sections in the other solver. For an Abaqus to Nastran conversion, for example, *DASHPOT can be converted to *PELAS or PDAMP. The property mapping scheme can be edited under the *PropertyConversion block in the ConfigurationFile.txt file.

Please note that the property conversion scheme and corresponding element conversion scheme must be consistent. For example, if you define *CONNECTOR SECTION to PBUSH at the property mapping scheme, the corresponding element CONN3D2 must map to CBUSH in the element mapping scheme.

For SOLID SECTION the converter will always convert to PSOLID unless the property has a data line indicating a crossectional area for a truss element. In this case conversion results in a PROD property.

For BEAM (GENERAL) SECTION the algorithm automatically decides which property to convert to depending on the element type chosen in the ElementTypeConversion section of the ConfigurationFile.txt. For example, if you want to convert B31 elements to CBAR, the beam property will get converted to a PBAR or PBARL property. If you choose to convert B31 elements to CBEAM, then the converter creates PBEAM or PBEAML properties accordingly. The same logic applies to B32 elements; the difference is that they are changed to first order beam elements first on conversion.

Abaqus type

Nastran type

*BEAM GENERAL SECTION

PBAR(L), PBEAM(L)

*BEAM SECTION

PBAR(L), PBEAM(L)

*CONNECTOR SECTION

PELAS,PBUSH

*DASHPOT

PELAS,PDAMP

*GAP

PGAP

*MASS

CONM2

*MEMBRANE SECTION

PSHELL

*ROTARY INERTIA

CONM2

*SHELL GENERAL SECTION

PSHELL

*SHELL SECTION

PSHELL

*SOLID SECTION

PSOLID

*SPRING

PELAS, PBUSH

*SOLID SECTION (Homogeneous)

PROD

*SHELL GENERAL SECTION (Homogeneous)

PSHELL

*SHELL SECTION (Homogeneous)

PSHELL

*SHELL GENERAL SECTION (User)

PSHELL

*SHELL SECTION (Composite)

PCOMP, PCOMPG

*SHELL GENERAL SECTION (Composite)

PCOMP, PCOMPG

 

Materials


The table below shows supported material mapping between Abaqus and Nastran. The material mapping scheme can be edited under *PropertyConversion block in the ConfigurationFile.txt file.

Abaqus type

Nastran type

*MATERIAL

MAT1, MAT4, MATT1, MATS1

*CONNECTOR BEHAVIOR

PBUSH, PELAS

 

Loads


HM loads have two basic attributes – configuration (or config) and type. The supported load "configs" are: force, moment, constraint, pressure, temperature, flux, velocity, acceleration and equation. The load "type" defines the solver specific type of a particular configuration. For example, pressure load can be any of the following Nastran types: PLOAD, PLOAD2 or PLOAD4. The Load Types panel shows all supported load configurations and their types for a user profile.

The converter also converts distributed surfaces loads (*DLSOAD) applied on faces of shell or solid elements into pressure loads (PLOAD4).

For a specific configuration, you can map any supported Abaqus load type to any supported Nastran load type. The conversion tool does not support conversion across load configurations. The load mapping scheme can be edited under the *BCsTypeConversion block in the ConfigurationFile.txt file. You need to provide both configuration and type information to specify the mapping scheme as shown below:

HM configuration

Abaqus type

Nastran type

temperature

TEMPERATURE

TEMP

pressure

DLOAD

PLOAD,PLOAD2,PLOAD4

Constraint

ACCELERATION

SPCD

 

VELOCITY

SPCD

 

BOUNDARY

SPC,SUPORT

moment

CLOAD

MOMENT

force

CLOAD

FORCE

equation

EQUATION

MPC

 

Sets

Abaqus type

Nastran type

*NSET

SET

*ELSET

SET

 

Systems

Abaqus type

Nastran type

*ORIENTATION

CORD2C,CORD2R,CORD2S

*SYSTEM

CORD2C,CORD2R,CORD2S

*TRANSFORM

CORD2C,CORD2R,CORD2S

*TRANSFORM- USER DEFINED NSET

CORD2C,CORD2R,CORD2S

 

Load Steps and Analysis Type


The conversion tool maps between Abaqus steps and Nastran subcases. It does not convert Abaqus analysis type to the solution type. You must define it manually using the Load Step browser.

The converter converts *STEP into SUBCASE. Load collector references are maintained upon conversion. If multiple load collectors of a particular step contain constraints, an SPCADD card is created automatically. The same happens in case of loads in separate load collectors; a new LOAD card is created on conversion.

 

 

See Also:

Abaqus Conversion Tools