HyperMesh and BatchMesher

Gauge Panel

Gauge Panel

Previous topic Next topic Expand/collapse all hidden text  

Gauge Panel

Previous topic Next topic JavaScript is required for expanding text JavaScript is required for the print function  

Location:   Analysis page – Optimization panel

 

The Gauge panel allows you to create design variables (DESVAR) and property relation (DVPREL1) cards for shell and composite laminate components (PSHELL, PCOMP, and PCOMPG) selected for size optimization.

Use this panel when several shell or composite components have the same or different shell thickness, ply thickness, or ply angle, and size optimization is performed with the shell thickness, ply thickness, or ply angle as the design variable.

Use the Gauge panel to create design variables (DESVAR) and property relation (DVPREL1) cards for shell and composite laminate components (PSHELL, PCOMP, and PCOMPG) selected for size optimization.

Use this panel when several shell or composite components have the same or different shell thickness, ply thickness, or ply angle, and size optimization is performed with the shell thickness, ply thickness, or ply angle as the design variable.

 

Subpanels and Inputs


The Gauge panel contains the following subpanels and command buttons:

hmtoggle_arrow1Create

Panel Inputs

Input

Action

value from property / initial value

Value from property uses the selected PSHELL, PCOMP or PCOMPG card images to assign initial values for shell thickness, ply thickness, or ply orientation.

Initial value = allows you to assign a nominal initial value for all selected components.

lower bound / lower bound %

Use lower bound= to choose a specific value for the lower boundary.

Use lower bound % = to choose the lower bound as a percentage of the initial value.

upper bound / upper bound %

Use upper bound= to choose a specific value for the upper boundary.

Use upper bound % = to choose the upper bound as a percentage of the initial value.

props

Select the property.

Note:You can input actual values for lower bound and upper bound, or select a percentage (%) of the initial value.  For example, if the initial value = 10, lower bound % = -20, and upper bound % = 20, then after exporting the file the lower bound and the upper bound are automatically changed to 8 and 12, respectively.

 

hmtoggle_arrow1Update

Panel Inputs

Input

Action

desvar

Name for the design variable

type

Entity type

props

Select the property.

minimum thickness

Enter the minimum thickness or select zero to be the minimum.

maximum thickness

Choose to use the thickness value from the selected property, or enter a thickness value.

 

hmtoggle_arrow1Parameters

Panel Inputs

Input

Action

desvar

Name for the design variable

minmemb off / mindim =

Enter a value for the member size control, or toggle the switch to off.

stress constraint

Enter a value for the stress constraint, or toggle the switch to none.

fatigue constraint

Enter a value for the fatigue constraint, or toggle the switch to none.

For more information on member size control, see Member Size Control for Free Size Optimization in the OptiStruct online help.

 

hmtoggle_arrow1Composites

Panel Inputs

Input

Action

desvar

Name for the design variable

laminate thickness: min thickness = /off

Enter a value for the laminate thickness minimum, or toggle the switch to off.

laminate thickness: max thickness = /off

Enter a value for the laminate thickness maximum, or toggle the switch to off.

ply thickness: no. of constraints

Enter the number of constraints for the ply thickness.

ply percentage: no. of constraints

Enter the number of constraints for the ply percentage.

balance: no. of constraints

Enter the number of constraints for the balance.

constant: no. of constraints

Enter the number of constraints for the constant.

 

hmtoggle_arrow1Pattern Grouping

Panel Inputs

Input

Action

desvar

Name for the design variable

pattern type

Select the pattern type.

anchor node

 

node id / coordinates

 

first node

 

second node

Used for 2-plns sym or 3-plns sym types.

ucyc

The number of repetitions in 360 degrees. Used for cyclic or cyc 1-pln types.

 

hmtoggle_arrow1Pattern Repitition

Panel Inputs

Input

Action

desvar

Name for the design variable

master / slave / none

Determine whether you are establishing a master coordinate system, a slave design variable, or neither.

system /coordinates

Choose to manually enter the values for the coordinate system, or to graphically select the system.

global system / local system

Reference coordinate system

anchor

Select the anchor node.

sx /sy /sz

x, y and z scale factors.

 

hmtoggle_arrow1Command Buttons

The following action buttons appear throughout the subpanels:

Input

Action

create

Create the design variable.

edit

Opens the property collector panel to edit the property.

reject

Reverts the most recent changes.

review

Review the load in the graphic area.

update

Update the load with the most recent changes.

return