You can edit the contour legend in the Edit Legend dialog, which is accessed by clicking Edit Legend on the Contour, Tensor, and Vector panels.

edit_legend

Edit Legend dialog

The following options are available in the dialog:

Legend

 

 

Type

Fixed Scale - displays a global maximum and minimum value in the legend for the time steps HyperView has already processed.

Dynamic Scale - changes the legend with respect to the maximum and minimum values of each time step or simulation.

 

Position

Select the position of the legend within the HyperView window (Upper left, Upper right, Lower left, or Lower right).

 

Interpolation

Linear - divides color bands into equal ranges in a linear manner.  This is the default interpolation setting.

Log interpolation is useful for looking at results which have a large range of values (for example, life cycle results in a fatigue analysis).  It is important to note that only the color bands are interpolated in a logarithmic manner, the actual results are not.  You can use the Expression Builder and Result Math to obtain a logarithmic value of any result.

Note:   If the result value range is invalid, the legend cannot be set to Log (a notification message “Unable to set the legend filter” is displayed in the status bar at the bottom left corner of the window).  If legend is already set to Log, changing the result data type, or applying an offset to contour or change in loadstep/loadcase will cause an invalid value range and the legend will be restored to Linear scale (a warning message “Current result range is invalid for log legend. Legend has been switched back to Linear scale” will be written into the message log).  Any attempts to override invalid Logarithmic scale legend values will be rejected in the GUI with appropriate messages posted to the status bar or the message log.

Values and
colors

 

 

Numeric format

Scientific - displays the legend values in scientific format.

Engineering - displays the legend values in engineering format.

Fixed - displays the legend values in a fixed format.

Auto - displays the legend values in the format specified in the preference file default setting.

Note: *DefineNumericFormat() can be added in the preferences_post.mvw file, to define the default setting for numerical presentation in the legend.  See Preference Files for more information on specifying defaults in a preference file.

 

Numeric
precision

You can increment the current value from 1 to 12 decimal points.

 

Number of
levels

Displays more or less contour bands along with their respective ranges.  The minimum number of bands you can display in a legend is 2; the maximum is 32.

 

Reverse

Reverses the legend values assigned to the contour bands.

 

Interpolate

Interpolates the colors in between the two colors that you select.  After clicking Interpolate, use the legend within this dialog to select a color to interpolate from and a color to interpolate to.  When you select Interpolate, the program displays contour colors for each frame based on the linearly interpolated values between the zero value in the undeformed shape and the solver reported values.

Legend file

 

 

Open

Opens a previously saved legend in Tcl format.

 

Save

Saves the current legend in Tcl format.

Save options

Select any of the options listed to save them along with the current legend.

Font attributes allows you to save the current font settings.

Header

Displays the legend header.  To remove the header, deactivate the check box.  To enter a new header, highlight the existing text, type in a new header and click Apply.

Click the font button, font_button, to change the font style and size.

Footer

Displays the legend footer.  To remove the footer, deactivate the check box.  To enter a new footer, highlight the existing text, type in a new header and click Apply.

Click the font button, font_button, to change the font style and size.

Title

Displays the title of the legend.  The title reflects the settings used to generate the contour and cannot be changed.  Click the font button, font_button, to change the font style and size.

Values

Click on a color to select a new color from the color palette.

Click on the value to set a user-defined value.  The number is displayed in bold face style to indicate the custom setting.

To reset the number, click on the number and erase all digits.  The legend values between two custom settings are linearly interpolated.


Maximum/
Minimum

Displays the maximum and minimum legend values.  Deselect the option to remove the minimum and maximum values from the display.


Local maximum/
Local minimum

Displays the local maximum and local minimum of a particular time step or simulation.  This option is available only in transient mode with a static legend.


Entity label

Displays the entity label for the maximum, minimum, local maximum, and local minimum legend values (if these options have been selected).   Deselect the option to remove the entity label from the display.


By Model

Displays the maximum and minimum legend values for each overlaid model separately.

This option is for multiple/overlaid models only!


Transparency

Displays the legend with a transparent background.   Deselect the option to display the legend with the background color which is currently displayed in the color box (located to the right of the Transparency option).


Fill color

Displays the legend with a color background (if the Transparency option is deselected).  To select a color for the legend background:  click the color box to display the color palette, select a color, and click OK.


font_button

Click the font button to change the font type, style, and size.

The legend is displayed on the right side of the dialog, allowing you to preview changes as you make them.

Default

Resets the default legend properties.

Apply

Click Apply to apply the changes made to the legend.

OK

Click OK to apply the changes and exit the Edit Legend dialog.

Cancel

Click Cancel to disregard changes and exit the dialog.

Important Note - Some of the options in this dialog will change depending on the selections made in the panel.  Whenever MaxLayer, MinLayer, or ExtremeLayer layers are selected in the panel, a category dialog will be displayed.  See the Edit Category Legend topic for additional details.

How Do I....

hmtoggle_plus1Edit the Contour, Vector, or Tensor panel legend:
1.From the Contour, Vector, or Tensor panel, click Edit Legend. The Edit Legend dialog is displayed.
2.Select the attributes that you want to apply to the legend. The changes are previewed on the sample legend, located on the right side of the dialog.
3.Click Apply.
4.Click Default to restore the default values for the legend.
5.Click OK to exit.
hmtoggle_plus1Interpolate colors using the Contour, Vector, or Tensor panel legend:
1.From the Contour, Vector, or Tensor panel, click Edit Legend. The Edit Legend dialog is displayed.
2.Click Interpolate.
3.Select a color to interpolate from from the legend displayed in the legend preview.
4.Select a color to interpolate to from the legend displayed in the legend preview. The color bars between the two colors you selected are interpolated.

 

See Also:

List of Tcl/Tk poILegend Class Commands

Using Scalable Fonts under Linux to Render Text