• | *SPECIFIC HEAT converted to CP in MAT4 |
• | *STEP, STATIC converted to ANALYSIS type NLSTAT if Abaqus model contains *PLASTIC or *SPRING/*DASHPOT with NONLINEAR option or *HYPERELASTIC |
• | *STATIC, STABILIZE converted to PARAM,EXPERTNL,CNTSTB |
• | *CLEARANCE converted to CLEARANCE option in PCONT |
• | *FRICTION converted to PCONT with m1 |
• | *TIE, POSITION TOLERANCE mapped to SEARCHDIS parameter in TIE |
• | *CONTACT PAIR with ADJUST is mapped ADJUST parameter in CONTACT |
• | *CONTACT PAIR, TIED is converted as FREEZE option in CONTACT |
• | *CONTACT PAIR, SURFACE to SURFACE is converted as S2S option in DISCRET field of CONTACT card |
|