Block Format Keyword
/ALE/LINK/VEL - Defines Links on Grid Velocities
Description
With ALE links on grid velocities, given nodes are linked to the given master grid velocities. Either a direction or a combination of directions can be specified.
Format
(1)
|
(2)
|
(3)
|
(4)
|
(5)
|
(6)
|
(7)
|
(8)
|
(9)
|
(10)
|
/ALE/LINK/VEL/alelink_ID
|
alelink_title
|
node_ID1
|
node_ID2
|
grnod_ID
|
grid_dof
|
Iform
|
|
|
|
|
|
Tstart
|
Tstop
|
|
|
|
Field
|
Contents
|
SI Unit Example
|
node1
|
First master node number
(Integer, maximum 10 digits)
|
|
node2
|
Second master node number
(Integer, maximum 10 digits)
|
|
grnod_ID
|
Node group to which ALE link is applied.
(Integer, maximum 10 digits)
|
|
grid_dof
|
A combination of X, Y, and Z
=0: free DOF
=1: fixed DOF
(Booleans)
(see codes for grid velocity direction)
|
|
Iform
|
Formulation flag
(Integer)
= 0 (linear):
= 1 (maximum):
WN = WM1 if
WN = WM2 if
= -1 (minimum):
WN = WM1 if
WN = WM2 if
|
|
Tstart
|
Start time
(Real)
|
|
Tstop
|
Stop time
(Real)
|
|
|
(1)-1
|
(1)-2
|
(1)-3
|
(1)-4
|
(1)-5
|
(1)-6
|
(1)-7
|
(1)-8
|
(1)-9
|
(1)-10
|
|
|
|
WX
|
WY
|
WZ
|
|
|
|
|
Field
|
Contents
|
WX
|
Code for grid velocity in direction X
=0: free DOF
=1: fixed DOF
(Boolean)
|
WY
|
Code for grid velocity in direction Y
=0: free DOF
=1: fixed DOF
(Boolean)
|
WZ
|
Code for grid velocity in direction Z
=0: free DOF
=1: fixed DOF
(Boolean)
|
|
2. | ALE links can also be added during an Engine run (Engine Input). RADIOSS will superimpose the grid velocities if different ALE links are defined in both Starter and Engine for the same node. |
3. | The grnd_ID input is mandatory. |
4. | Formulation 0 needs an unsortable group of nodes (/GRNOD/NODENS). |
|
See Also:
/ALE/LINK/VEL