HyperWorks Solvers

/ALE/CLOSE

/ALE/CLOSE

Previous topic Next topic Expand/collapse all hidden text  

/ALE/CLOSE

Previous topic Next topic JavaScript is required for expanding text JavaScript is required for the print function  

Block Format Keyword

/ALE/CLOSE - Treatment of Elements Closure

Description

Describes the treatment of element closure.

Format

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

/ALE/CLOSE/prop_ID

htest

hclose

 

 

 

 

 

 

hmtoggle_plus1Flag Definition

Field

Contents

prop_ID

Property identifier

(Integer, maximum 10 digits)

htest

Element size to activate element closure

Default = 0.0  (Real)

hclose

Element size to activate resistance to flow

Default = 0.1*htest  (Real)

hmtoggle_plus1Comments
1.This option can be used with fluid properties /PROP/FLUID (TYPE14) or /PROP/POROUS (TYPE15).
2.The algorithm can handle closure in any but in only one direction, namely when one element is already or is becoming flat.