Subcase Information Entry
ANALYSIS - Run Control and Solution Sequence Identifier
Description
The ANALYSIS command can be used in the I/O Options section to request that only a finite element analysis be performed (optimization input is ignored). It may also be used in the I/O Options or Subcase Information sections to identify the solution sequence for all subcases or for individual subcases, respectively.
Format
ANALYSIS = option
Argument |
Options |
Description |
|
option |
<ONLY, OPTSKIP, STATICS, NLSTAT, MODES, MCEIG, BUCK, DFREQ, MFREQ, DTRAN, MTRAN, DFOUR, MFOUR, HEAT, NLHEAT, MBD, EXPDYN, FATIGUE, RANDOM> Default = ONLY |
The first two options ONLY and OPTSKIP refer to the run control functionality of the ANALYSIS command: |
|
ONLY: |
Performs finite element analysis run only. Optimization inputs are checked but ignored. |
||
OPTSKIP: |
Performs finite element analysis run only. Optimization inputs are ignored. |
||
The remaining options refer to the solution sequence identification functionality of the ANALYSIS command: |
|||
STATICS: |
Linear static or nonlinear quasi-static gap analysis. |
||
NLSTAT: |
Small displacement nonlinear analysis. |
||
HEAT: |
Linear steady-state heat transfer analysis or linear transient heat transfer analysis. |
||
NLHEAT: |
Nonlinear steady-state heat transfer analysis. |
||
MODES: |
Normal modes analysis. |
||
MCEIG: |
Modal complex eigenvalue analysis. |
||
BUCK: |
Linear buckling analysis. |
||
DFREQ: |
Direct frequency response analysis. |
||
MFREQ: |
Modal frequency response analysis. |
||
DTRAN: |
Direct transient response analysis (linear and nonlinear) |
||
MTRAN: |
Modal transient response analysis. |
||
DFOUR: |
Direct transient response analysis through Fourier transformation. |
||
MFOUR: |
Model transient response analysis through Fourier transformation. |
||
MBD: |
Multi-body dynamics analysis. |
||
EXPDYN: |
Geometric nonlinear explicit dynamic analysis. |
||
FATIGUE: |
Fatigue analysis. |
||
RANDOM: |
Random Response analysis. |
1. | ANALYSIS=ONLY or ANALYSIS=OPTSKIP are only applicable in the I/O Options section. |
2. | ANALYSIS=ONLY or ANALYSIS=OPTSKIP may be used in combination with one of the other ANALYSIS options. |
3. | When ANALYSIS=ONLY or ANALYSIS=OPTSKIP are used, all elements (including design elements) are treated as non-design elements. |
4. | When ANALYSIS=ONLY or ANALYSIS=OPTSKIP are used, all properties and grids referenced by size and shape variables will be set at the values on the associated property and GRID data. |
See Also: