HyperWorks Solvers

CMDE

CMDE

Previous topic Next topic No expanding text in this topic  

CMDE

Previous topic Next topic JavaScript is required for expanding text JavaScript is required for the print function  

I/O Options Entry

CMDE - Output Request

Description

The CMDE command can be used above the first SUBCASE or within a SUBCASE definition to request component modal synthesis damping energy output for all subcases or individual subcases, respectively.

Format

CMDE(format_list,MODES=mset,TYPE=type) = option

Argument

Options

Description

format

<H3D, blank>

Default = blank

H3D:

Results are output in Hyper3D format (.h3d file).

blank:

Results are output in all active formats for which the result is available.

 

type

<AVERAGE, AMPLITUDE, PEAK>

Default = AVERAGE

AVERAGE:

The average of the energy is output.

AMPLITUDE:

The amplitude of the energy is output.

PEAK:

The peak energy is output. This is the sum of AVERAGE and AMPLITUDE.

 

mset

<ALL, SID, TOTAL>

Default = ALL

ALL:

Modal energy is output for all modes.

SID:

If a set ID is given, modal energy is output only for modes listed in that set.

TOTAL:

Only the total energy is output.

 

option

<YES, ALL, NO, NONE>

Default = ALL

YES, ALL, blank:

Modal energy is output.

NO, NONE:

Modal energy is not output.

Comments

1.When the CMDE command is not present, component modal synthesis damping energy is not output.
2.Component modal synthesis damping energy output is only available for frequency response analysis (both direct and modal methods). It is intended for use when external CMS superelements are used.
3.Multiple formats are allowed on the same entry; these should be comma separated. If a format is not specified, this output control applies to all formats defined by the OUTPUT command, for which the result is available. See Results Output for information on which results are available in which formats.
4.Multiple instances of this card are allowed; if instances are conflicting, the last instance dominates.
5.For optimization, the frequency of output to a given format is controlled by the I/O option OUTPUT.

See Also:

I/O Options Section

I/O Options by Function

The Input File