solution_seq_table_13A

Key:

R

Required Data Selector.

O

Optional Data Selector. All optional data selectors can be set equal to zero in order to override inheritance from default settings (data selectors appearing before the first subcase).

E

Either one of the selectors marked E are required, both are optional.

A

Exactly one selector marked A is required.

      

Data selector may be defined above the first subcase, in which case it is used in any subcase where it is allowed (as long as it has not been defined specifically).

**

METHOD(Fluid) and SDAMPING(Fluid) are allowed when the model does not contain fluid parts, but a warning is issued in such cases.

Direct Frequency and Transient solutions only allow reference of FREQ, FREQ1 and FREQ2. Modal Frequency and Transient solutions also allow reference of FREQ3, FREQ4 and FREQ5.