HyperWorks Solvers

FLSPOUT (Not Supported in 11.0 or Later Versions)

FLSPOUT (Not Supported in 11.0 or Later Versions)

Previous topic Next topic No expanding text in this topic  

FLSPOUT (Not Supported in 11.0 or Later Versions)

Previous topic Next topic JavaScript is required for expanding text JavaScript is required for the print function  

I/O Options and Subcase Information Entry

FLSPOUT – Output Request

Description

The FLSPOUT command can be used in the I/O Options section to control output of modal participation factors for coupled fluid-structure models.

Format

FLSPOUT(argument = option, argument = option, ...)

Argument

Options

Description

FLUIDMP

<ALL, NONE>

Default = NONE

Requests fluid participation calculation of fluid response on selected fluid points.

ALL:

Requests that all the fluid modes extracted be used.

NONE:

Requests no participation calculation.

 

GRIDFMP

<SID>

No default

Requests inclusion or exclusion of specific fluid grids to be used in all the requested types of participation calculations.

SID:

Set identification number - Results are output only for fluid grids listed in the selected set.


FEPS

<Real>

Default = 1.0e-11

Filter Threshold for fluid participation.


ARF

<Real>

Default = 1.0e-11

Acceptance ratio for fluid participation.


STRUCTMP

<ALL, NONE>

Default = NONE

Requests structural, load, and panel participation calculations on the selected fluid points.

ALL:

Requests that all the structural modes extracted be used.

NONE:

Requests no participation calculation.


PANELMP

<ALL>

Default = ALL

Requests inclusion or exclusion of panel participation calculations on the selected fluid points.

ALL:

Requests that all the panels defined be included in the participation calculations on the selected fluid points.


SEPS

<Real>

Default = 1.0e-11

Filter Threshold for structural participation.


ARS

<Real>

Default = 1.0e-11

Acceptance ratio for structural participation.


PSORT

<ABSOLUTE>

Default = ABSOLUTE

Requests type of sort.

Comments

1.GRIDFMP is required for all FLSPOUT statements.
2.FLUIDMP and STRUCTMP are required when PANELMP is defined.
3.The output file name for modal participation is *.modal.

See Also:

I/O Options Section

I/O Options by Function

The Input File