I/O Options Entry
OMODES - Output Control
Description
The OMODES command can be used in the I/O Options or Subcase Information sections to request a set of modes for output requests for all subcases or for individual subcases, respectively. This command is applicable for normal modes and linear buckling solution sequences only.
Format
OMODES = option
Argument |
Options |
Description |
|
option |
<ALL, SID> Default = ALL |
ALL, blank: |
Output is calculated for all modes. |
SID: |
If a set ID is given, output is calculated for only modes listed in that set. |
1. | When OMODES is not present, output is for all modes. |
2. | The SET definition referenced by the OMODES card must be an integer value set. |
3. | This output control is not available for frequency response subcases; OFREQUENCY should be used instead. |
4. | If both the OMODES and OFREQUENCY requests appear, the OMODES request takes precedence. |
See Also: