HyperWorks Solvers

PARAM, FLIPOK

PARAM, FLIPOK

Previous topic Next topic No expanding text in this topic  

PARAM, FLIPOK

Previous topic Next topic JavaScript is required for expanding text JavaScript is required for the print function  

Parameter

Values

Description

FLIPOK

<NO, YES>

Default = NO

If YES, severely distorted and possibly inverted elements will be accepted by OptiStruct. This is limited to first order Tetrahedral (CTETRA) and Triangular (CTRIA3) elements.

If NO, severely distorted elements will not be accepted by the solver, and the solution will be terminated with an error to avoid inaccurate results.

Note

PARAM, FLIPOK, YES can be introduced to force OptiStruct to run models with severely distorted and possibly inverted elements (CTETRA/CTRIA3). Since such models contain severely distorted and inverted elements, it is your responsibility to further validate the analysis or optimization results for accuracy, if this parameter is used.