HyperWorks Solvers

PARAM, GYROAVG

PARAM, GYROAVG

Previous topic Next topic No expanding text in this topic  

PARAM, GYROAVG

Previous topic Next topic JavaScript is required for expanding text JavaScript is required for the print function  

Parameter

Values

Description

GYROAVG

<0, -1>

Default = 0

This parameter is used to select the frequency response analysis formulation type for rotor dynamics analysis.

PARAM, GYROAVG, 0

If this formulation is selected, the frequency-dependent rotor dynamics terms are calculated for each frequency. A frequency-dependent looping option is activated, however, the run time is higher compared to PARAM, GYROAVG, -1 as the calculation process has to be repeated for each frequency in the specified range.

PARAM, GYROAVG, -1

If this formulation is selected, frequency-dependent looping does not occur and an average frequency method is used to calculate the rotor dynamic terms. The run time is lower compared to PARAM, GYROAVG, 0 as this option avoids intensive calculations for each frequency. PARAM, WR3 and PARAM, WR4 must be specified for this formulation to include rotor damping.

Refer to Rotor Dynamics in the User’s Guide for more details.