RNFLOW – Output Request
The RNFLOW command can be used in the I/O Options or Subcase Information sections to request fatigue damage results output for all fatigue subcases or individual fatigue subcases, respectively.
RNFLOW (format) = option
Argument |
Options |
Description |
|
format |
<OPTI, blank> Default = blank |
OPTI: |
Results are output in OptiStruct results format (.rnf file). |
blank: |
Results are output in all active formats for which the result is available. |
||
|
|||
option |
<YES, ALL, NO, NONE, SID> Default = ALL |
YES, ALL, blank: |
Results are output for all elements. |
NO, NONE: |
Results are not output. |
||
SID: |
If a set ID is specified, results are output only for elements listed in that set. |
1. | Fatigue results via the RNFLOW entry are available only for OPTI format in the .rnf file. |
2. | Multiple instances of this card are allowed; if instances are conflicting, the last instance dominates. |
3. | This entry can be used to output the Rainflow Cycle count history for a particular fatigue subcase. The Cycle number, Stress Range, Mean Stress, and Damage, for each fatigue event for each element are output to <filename>.fatrf.<subcaseID>.rnf file. |
4. | For Multiaxial Fatigue, only proportional multiaxial subcase is supported for RNFLOW output. |
See Also: