HyperWorks Solvers

/TH/SECTIO

/TH/SECTIO

Previous topic Next topic Expand/collapse all hidden text  

/TH/SECTIO

Previous topic Next topic JavaScript is required for expanding text JavaScript is required for the print function  

Block Format Keyword

/TH/SECTIO - Time History - Section

Description

Describes the time history for sections.

Format

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

/TH/SECTIO/thgroup_ID

thgroup_name

var_ID1

var_ID2

var_ID3

var_ID4

var_ID5

var_ID6

var_ID7

var_ID8

var_ID9

var_ID10

Obj_ID1

Obj_ID2

Obj_ID3

Obj_ID4

Obj_ID5

Obj_ID6

Obj_ID7

Obj_ID8

Obj_ID9

Obj_ID10

hmtoggle_plus1Flag Definition

Field

Contents

thgroup_ID

TH group identifier

(Integer, maximum 10 digits)

thgroup_name

TH group name

(Character, maximum 100 characters)

var_ID1, ...n

Variables saved for TH (see table below)

(Character, maximum 8 characters)

Obj_ID1, ...n

Identifiers of the objects to be saved

(Integer)

hmtoggle_plus1TH Output Keyword & Variables

Keyword

Object saved

Variables

SECTIO

Section

FNX, FNY, FNZ, FTX, FTY, FTZ, M1, M2, M3, WORK, WORKR, MX, MY, MZ, F1, F2, F3, CX, CY, CZ, DFX, DFY, DFZ, DMX, DMY, DMZ

hmtoggle_plus1Table of available variables - Part 2

Keyword

Variable Group

Saved TH Variables

SECTIO

DEF

FN

FT

M

 

CENTER

GLOBAL

LOCAL

FNX, FNY, FNZ, FTX, FTY, FTZ, M1, M2, M3

FNX, FNY, FNZ

FTX, FTY, FTZ

M1, M2, M3

WORK, WORKR

CX, CY, CZ

FNX, FNY, FNZ, FTX, FTY, FTZ, MX, MY, MZ

F1, F2, F3, M1, M2, M3

hmtoggle_plus1Output for section
WORK: work of the forces and moments in the section, due to elements and interfaces saved in the section
DFX - FX error

th_group1


DFY - FY error

Errors in forces in the component section

DFZ - FZ error

DF2: quadratic error on forces in the component section

th_df2_equation

all nodes of the cut section

WORKR: work of the moments in the section, due to elements and interfaces saves in the section
DMX - MX error

th_group1


DMY - MY error

Errors in moments in the component section

DMZ - MZ error

DM2: quadratic error on moments in the component section

th_dm2_equation

all nodes of the cut section

KIN: translational kinetic energy (section nodes)
KINR: rotational kinetic energy (section nodes)

(Be aware that if you compare these values of the component model with those of the full model, it will be different because the nodal masses are different.)

DMVX - MVX error

th_group1


DMVY - MVY error

Errors in the translational velocities

DMVZ - MVZ error

DMV2: error translational kinetic energy
DMV/RX - MVRX error

th_group1


DMVRY - MVRY error

Errors in the rotational velocities

DMVRZ - MVRZ error

DMVR2: error rotational kinetic energy
EFW: external work of the component section. This is equal to the global external work if there is no other external work (due to another cut section, rigid wall friction, imposed velocities). It is equal to WORK with the difference of the inertia work force.

EFW = WORK - KIN ENERGY

FNX: normal force in direction X of global axis
FNY: normal force in direction Y of global axis
FNZ: normal force in direction Z of global axis
FTX: tangent force in direction X of global axis
FTY: tangent force in direction Y of global axis
FTZ: tangent force in direction Z of global axis
MX: Moment in direction X of global axis
MY: Moment in direction Y of global axis
MZ: Moment in direction Z of global axis
F1: Force in direction 1 of local axis
F2: Force in direction 2 of local axis
F3: Force in direction 3 of local axis
M1: Moment in direction 1 of local axis
M2: Moment in direction 2 of local axis
M3: Moment in direction 3 of local axis
CX: Coordinates of center of section in direction X of global axis
CY: Coordinates of center of section in direction Y of global axis
CZ: Coordinates of center of section in direction Z of global axis
hmtoggle_plus1Comments
1.Available names are listed in the two tables above.

In the first table, TH-variables are listed. If a TH-variable is requested, this variable is written.

In the second table, other variable groups are listed. If a variable group is requested, all the associated TH-variables are written at once.

2.The output of section force/moments errors works only for submodeling modelization, when ISAVE =2 is used in the full model and ISAVE =101 is used in the cut model.