Use the Design tab for a solver check run. Inspire (OptiStruct) is supported.
The model files generated during the pre-processing stage in Inspire can be validated for solver data accuracy.
File type |
From the File type drop-down menu, select Inspire. |
||||||||
Version |
Select the HyperWorks version number from the list. |
||||||||
Input file |
Click the file open icon, , to select the input file. |
||||||||
Output directory |
Click the file open icon, , to select your output directory to store your results file. |
||||||||
Out file comparison |
|
||||||||
Check Run |
Click Check Run to output your solution. |
||||||||
Status |
Under Result file, click Status to view the status of the Inspire model check run. |
||||||||
Html Report |
Generates an HTML report of your session information for any number of files run through the process. |
Solver Type |
From the Solver drop-down menu, select the results type to be compared. Option: Inspire. |
Tolerance |
The value used to set the tolerance for the difference in values between the reference and current version result files during comparison. Default - 1e-6 for Scalar, Tensor, and Vector, if not individually chosen. Scalar – Enter values if different for the scalar result type. Vector – Enter values if different for the vector result type. Tensor – Enter values if different for the tensor result type. User Defined - Set the individual tolerance value for all data types. Click Apply to set new values (enter the values in the text box). |
Result |
From the Result drop-down menu, select the result type. Options included H3D and OP2. Dynamically loads the selected result file type under Load Result on Run Solver. |
PPT/HTML Report |
Use one of these options to generate a PowerPoint or HTML report of the result value comparison. For Pass - This returns a detailed report containing one slide per data type across load cases. For Fail - In case of a failure, one slide per load case for each datatype is published so that it is easy to identify the load case that contains a difference in values. |
Current/Reference |
The Current and Reference sections contain the following options: Version - Select the solver version from the drop-down menu. Run Solver - This is required if the result files are not available, and the solver needs to be run to generate result files (for only one or both versions). The Inspire(OptiStruct) solvers invoked in batch mode and the model selected through Load Model are run, and the result file path is populated in the Load Result field. Load Model - Select the HyperView/Inspire model file. Load Result - Select the HyperView results file (if Run solver is not selected). |
Output directory |
Click the file open icon to select your output directory to store your results. |
SubcaseSimulationResult Type |
Select any combination of Subcase, Simulation and Result type from the populated areas. Click All to select all items listed. |
Apply |
Click Apply to generate data to compare the results with combinations of the following: Subcase, Simulation and Datatype. |
Compare result |
The Compare result section displays the current file and the corresponding Reference file. Click Report to display the diff report detailing the differences between files. |
Message log file |
A dynamically created message log file that displays the current status of processes in progress. Click the Status/Diff button to display the respective report. The message log file is a text file and is saved to your output directory. |
Html Report |
Generates an HTML report of your session information for any number of files run through the process. |