HyperWorks Tools

Result Tab

Result Tab

Previous topic Next topic Expand/collapse all hidden text  

Result Tab

Previous topic Next topic JavaScript is required for expanding text JavaScript is required for the print function  
hmtoggle_plus1greySolver result comparison HV versions

The Solver result comparison HV versions tab ensures that HyperView does not deprecate any result information after post-processing.

Reference result file (result file already validated) is read in different versions of HyperView.
Any combination of results from different data types, simulation and subcases are exported for each HyperView version and compared.
Any difference would trigger the problem and would be reported.

Different levels of verification and validation include:

Verification of the reference result files across two versions of HyperView (with the same solver version results).

mfg_sol_hx_result_solver_result_comp_hv_version

Solver Type

From the Solver Type drop-down menu, select a solver whose results are to be compared.  Options include:

Hyper3D

Tolerance

The value used to set the tolerance for the difference in values between the reference and current version result files during comparison.

From the Tolerance drop-down menu, select default, scalar, tensor, or vector.

Default - 1e-6 for all three (Scalar, Tensor, and Vector, if not individually chosen).

Scalar – Enter values if different for the scalar result type.

Vector – Enter values if different for the vector result type.

Tensor – Enter values if different for the tensor result type.

Apply

Click Apply to set the new values (enter the values in the text box).

PPT Report

HTML Report

PPT Report - Select this option to have your results displayed in a PowerPoint report.

HTML Report - Select this option to have your results displayed in HTML.

Use one of the following options to generate a PowerPoint or HTML report of the result value comparison.

Pass - This returns a detailed report containing one slide per data type across the load cases.

Fail - In case of a failure, one-slide-per-load-case for each data type is published so that it is easy to identify the load case that contains a difference in values.

Current and Reference

The Current and Reference sections contain the following options:

Version - Select the HyperView version from the drop-down menu.

Load Model - Select the HyperView model file.

Load Result - Select the HyperView results file.

Output directory

Click the file open iconhwd_bmp00005to select your output directory to store your results information.

Apply

Click Apply to store your results information.

Subcase

Simulation

Result Type

Select any combination of Subcase, Simulation and Result type from the populated areas.

Click All to select all items listed.

Apply

Click Apply to generate data to compare the results with combinations of all the above: subcase, simulation and datatype.

Compare result

The Compare result section displays the current file and the corresponding reference file.  Click Report to display the diff report detailing the differences between files.

Messages

Click Messages to view any error messages.

Html Report

Generates an HTML report of your session information for any number of files run through the process.