From the Display sub-tab, select one of the following methods to display and rank the orders: 2D Line, 3D Surface, or Bar. To activate this tab, you must first load a file from the Load tab.
NVH-Utilities Browser - Display tab (Order Analysis)
Option |
Description |
|
2D Line |
Display |
Select the type of curve to display. |
RPM range |
Select the RPM range that the order curves should be plotted within. |
|
No. of highest order |
After defining the RPM range, organize the display by selecting the number of highest orders. |
|
Rank by |
Define the method that is used to rank orders with one of the following options: Magnitude - Orders are ranked by the magnitude of the order. Available for Bar plot. RSS Magnitude - Orders are ranked by the root sum of squares of the magnitude of the order at selected frequencies. Available for 2D Line and 3D Surface plots. |
|
|
Display Options |
The Display Options dialog allows you to further customize the plot. |
|
Display |
Click Display to create and display the plot. |
3D Surface |
Creates a 3D Surface plot of the response within an RPM range. RPM range indicates the available range, based on your results file. Using the From and To fields, you can customize your own RPM range. All other options are similar to those for the 2D Line plot. |
|
Bar |
Creates a Bar plot of the response at a specific frequency or RPM. Enter a specific RPM in the Specific RPM field, or use the slider bar to select an RPM value. When you use the slider bar to select an RPM, a red line is displayed on the response plot and is dragged simultaneously as you drag the slider bar. All other options are similar to those for the 2D Line plot. |
NVH-Utilities Browser – 2D Line plot (Order Analysis)
NVH-Utilities Browser – 3D Surface plot (Order Analysis)
NVH-Utilities Browser – Bar plot (Order Analysis)