Location: Analysis page
The Loadsteps panel is available only when the Nastran or OptiStruct user profile is loaded. It is used to generate Nastran and OptiStruct loadstep definitions. The panel creates HyperMesh loadstep entities. These loadstep entities directly correspond to Nastran and OptiStruct loadstep definitions.
The Loadsteps panel allows explicit selection of bulk data information for use in a loadstep. A type selector allows the user to define the type of analysis to be performed in a loadstep. Depending on the user profile, different analysis types are available. Each analysis type presents the user with a subset of selectors that are relevant to that type of analysis. A "generic" analysis type is also available which presents all selectors to the user.
The panel layout is different depending on the solver profile loaded; in general, OptiStruct offers more inputs than Nastran.
|
|
There are no subpanels on the Loadsteps panel. All inputs and button commands are located on the main panel.
Input |
Action |
name = |
Click this button to display a list of loadsteps, or type the name of a new loadstep into the text box. |
type: (switch) |
Use this switch to pick the loadstep type, such as linear static or heat transfer. The options available depend on the current user profile.
|
SPC |
Select a loadcollector with an SPCADD card image or a loadcollector with no card image containing SPC entries. |
LOAD |
Select a loadcollector with a LOAD, GRAV or RFORCE card image or a loadcollector with no card image containing FORCE, MOMENT, PLOAD, PLOAD2, PLOAD4, and SPCD entries. (If "LOADTEMP = shareid" is set in the OptiStruct configuration file, then a loadcollector with a TEMPD card image or a loadcollector with no card image containing TEMP entries may also be selected here). |
MPC |
Select a loadcollector with an MPCADD card image or a loadcollector with no card image containing MPC entries. |
SUPPORT1 |
Select a loadcollector with no card image containing SUPORT1 entries. |
NLPARM |
Select a loadcollector with an NLPARM card image. |
METHOD |
Select a loadcollector with an EIGRL card image |
FREQ |
Select a loadcollector with a FREQ, FREQ1, FREQ2, FREQ3, FREQ4 or FREQ5 card image |
SDAMPING |
Select a loadcollector with a TABDMP1 |
DLOAD |
Select a loadcollector with a DLOAD, TLOAD1, TLOAD2, RLOAD1, or RLOAD2 card image |
TSTEP |
Select a loadcollector with a TSTEP card image. For the OptiStruct user profile, you also need to choose TIME or FOURIER for TSTEP, indicating that a true transient or a fourier transform transient analysis is to be performed |
STATSUB |
Select a linear static loadstep definition. |
TEMP |
Select a loadcollector with a TEMPD card image or a loadcollector with no card image containing TEMP entries. (If "LOADTEMP = shareid" is set in the OptiStruct configuration file then a loadcollector with a TEMPD card image or a loadcollector with no card image containing TEMP entries should be selected by the LOAD selector and not by the TEMP selector). |
LOADSET |
Select a loadcollector with an LSEQ card image. |
IC |
Select a loadcollector with TIC card image. |
MBSIM |
Select a loadcollector with an MBLIN, MBSIM or MBSEQ card image. |
MLOAD |
Select a loadcollector with an MLOAD card image or a loadcollector with no card image that contains MBFRC, MBFRCC, MBMNT, or MBMNTC entries. |
MOTION |
Select a loadcollector with a MOTION card image or a loadcollector with no card image that contains MOTNG or MOTNGC entries. |
INVEL |
Select a loadcollector with an INVELB card image. |
CMSMETH |
Select a loadcollector with a CMSMETH card image. |
Other input data is automatically generated (the SUBCASE header) or may be added to the loadstep definition through the edit function (output requests, RESVEC).
The following action buttons appear:
Button |
Action |
next |
Advance to the next page of inputs. This button becomes inactive if you are already on the final page of inputs. |
prev |
Step back to the previous page of inputs. This button becomes inactive if you are already on the first page of inputs. |
create |
Create a new loadstep using the specified references. |
edit |
Open the timestep's card image in edit mode. |
update |
Modify the currently selected loadstep to use the references you have specified. |
review |
Opens a list of existing loadsteps so that |
return |
Exit the panel. |
An Alphabetical List of HyperMesh Panels