Load Step: CFILM: Define Tab
In the Define tab, define a *CFILM card on node sets only. HyperMesh does not support *CFILM on individual nodes.
Use the Define CFILM-Force/Moment on: Node sets option to define CFILM on node sets. The node set names are used in the *CFILM data lines instead of the individual nodes. Unlike Abaqus surfaces in HyperMesh, you can combine node sets with individual node IDs in the same *CFILM card.
|
This dialog has a node sets menu containing a list of the existing node sets. It also has a data line input table with the following columns:
Column |
Description |
Nodeset |
The name of the node sets. Node sets are added or removed using or , respectively. |
Area |
The area associated with the nodes. |
Sink temp |
Reference sink temperature. |
Film coef |
Reference film coefficient. |
For tips on entering information and navigating in the Define tab, see Step Manager Tab Environment.
The Define CFILM on: Node sets option has the following buttons:
Button |
Action |
Review Set |
Reviews the selected node sets by highlighting them in the HyperMesh graphics. Right-click Review to clear the review selections. |
Create/Edit Set.. |
Opens the Entity Sets panel in HyperMesh. When you finish creating/editing the set, click return. The Step Manager is updated with the new set appearing in the node set list. |
|
Adds the selected node set from the drop-down menu to the data line table on the right. |
|
Deletes the selected node set from the data line table. |
Review |
Reviews the selected node set in the data line table. Right-click Review to clear the highlighted selections. |
Update |
Updates the HyperMesh database with the data lines defined in the table. By default, HyperMesh does not create a display for loads defined with sets. |
See Also: