HyperWorks Release Notes

RADIOSS Interface 14.0 Release Notes

RADIOSS Interface 14.0 Release Notes

Previous topic Next topic Expand/collapse all hidden text  

RADIOSS Interface 14.0 Release Notes

Previous topic Next topic JavaScript is required for expanding text JavaScript is required for the print function  
hmtoggle_arrow1New User Profile

New user profile RADIOSS Block 140 is now available.

 

hmtoggle_arrow1Parameter Support

/PARAMETER is now supported for RADIOSS 12.0 and later.

Create, edit and reference /PARAMETER in other keywords with the Entity Editor.
Parameter type REAL, INTEGER, REAL_EXPR, INT_EXPR is supported. Parameter type TEXT is not supported.
Parameter expressions are evaluated at import and are updated during the session.
Parameters of type EXPR are created upon import of parameter references with a minus sign (-) before the prefix “&”.
All FE entities can be parametrized except loads, legal values, elements and node coordinates.
Parameterization of entity ID and attribute of type entity is not supported.
Unsupported parameterized entities are replaced with corresponding values during import, to avoid the loss of data.
The variables parameterized will be grayed out in the Card Editor so that it cannot be changed.

 

hmtoggle_arrow1Newly Supported Keywords

Supported up to RADIOSS Block 130, 140:

/FAIL/NXT
/UPWIND (Engine)

Supported as table entity in the Model browser in RADIOSS Block 110, 120, 130, 140

/INIBRI/STRA_F
/INIBRI/STRESS
/INIBRI/STRS_F
/PARAMETER/GLOBAL/REAL
/PARAMETER/GLOBAL/INTEGER
/PARAMETER/GLOBAL/REAL_EXPR
/PARAMETER/GLOBAL/INT_EXPR

Supported in RADIOSS Block 130, 140

/DT/THERM
/FAIL/TAB1
/MAT/LAW81
/MAT/LAW83

Supported in RADIOSS Block 110, 120, 130, 140

/ANIM/VECT/FREAC

 

hmtoggle_arrow1Updated Keywords

The following keywords were updated up to RADIOSS Block 140:

/FAIL/JOHNSON
/IMPL/SOLVER
/INISHE/STRS_F/GLOB
Interface type: 2,3,5,7,10,11,18,19,20 and 21
Material law: 20, 51, 58, 77 and 80
Property: SPH and type16

 

hmtoggle_arrow1Resolved Issues
PCOMPG are converted to /PROP/SH_SANDW when converting from OptiStruct to RADIOSS.
When converting a Nastran model to RADIOSS, an application error would occur if there were some unresolved IDs in the model to be converted.
When converting from OptiStruct to RADIOSS, an application error would occur if there was a “*” in the component name.
GRNOD/GENE was not shown in Solver browser.
Corrected the position of Einf and COE in /MAT/LAW78 under RADIOSS Block 130, 140.
Solver conversion from OptiStruct to RADIOSS gives application error due to unresolved IDs.
Added the blank line in /MAT/LAW51 for Iform=3 under RADIOSS Block 120, 130, 140.
For the transformation of type translation, if the vector was defined with 2 nodes, the direction in which the displacement was applied in the opposite direction compared to the solver.
Now Model browser's create submenu lists entities in alphabetical order.