HyperWorks Solvers

CDAMP1

CDAMP1

Previous topic Next topic Expand/collapse all hidden text  

CDAMP1

Previous topic Next topic JavaScript is required for expanding text JavaScript is required for the print function  

Bulk Data Entry

CDAMP1 – Scalar Damper Connection

Description

Defines a scalar damper element.

Format

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

CDAMP1

EID

PID

G1

C1

G2

C2

 

 

 

hmtoggle_plus1Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

CDAMP1

2

10

0

 

26

3

 

 

Field

Contents

EID

Unique element identification number.

No default (Integer > 0)

PID

PDAMP property entry identification number.

Default = EID (Integer > 0)

G1, G2

Geometric grid point or scalar point identification number.

Default = 0 (Integer > 0)

C1, C2

Component number in the displacement coordinate system specified by the CD entry of the GRID data.

Default = 0 (0 < Integer < 6)

Comments

1.Zero or blank may be used to indicate a grounded terminal G1 or G2 with a corresponding blank or zero C1 or C2. A grounded terminal is a point whose displacement is constrained to zero.
2.Scalar points may be used for G1 and/or G2, (with corresponding C1 and/or C2 of zero or blank). If only scalar points and/or grounded terminals are involved, it is more efficient to use the CDAMP3 entry.
3.The two connection points (G1, C1) and (G2, C2) must be distinct.
4.A scalar point specified on this entry need not be defined on an SPOINT entry.
5.When the SPSYNTAX setting on the SYSSETTING I/O option is set to CHECK (default) or STRICT, it is required for grid/component pairs (G#/C#) that the component be 0 or blank when the grid reference is a scalar point (SPOINT), and that the component be > 1 when the grid reference is a structural grid point (GRID). When SPSYNTAX is set to MIXED, it is allowed for grid/component pairs (G#/C#) that the grid reference be either a scalar point (SPOINT) or a structural grid point (GRID) when the component is 0, 1 or blank; interpreting all of these as 0 for scalar points and as 1 for structural grids. When the component is greater than 1, the grid reference must always be a structural grid (GRID).
6.Scalar damper elements are ignored in heat transfer analysis.
7.This card is represented as a spring or mass element in HyperMesh.

See Also:

Bulk Data Section

Guidelines for Bulk Data Entries

The Input File