CDAMP4 – Scalar Damper Property and Connection to Scalar Points Only

Description

Defines a scalar damper element that is connected only to scalar points and is without reference to a material or property entry.

Format

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

CDAMP4

EID

B

S1

S2

 

 

 

 

 

hmtoggle_plus1Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

CDAMP4

16

-2.6

4

9

 

 

 

 

 

Field

Contents

EID

Unique element identification number.

No default (Integer > 0)

B

Scalar damper value.

No default (Real)

S1, S2

Scalar point identification numbers.

Default = 0 (Integer > 0; S1 ≠ S2)

Comments

1.S1 or S2, but not both, may be blank or zero, indicating a constrained coordinate.
2.This single entry completely defines the element since no material or geometric properties are required.
3.Only one scalar damper element may be defined on a single entry.
4.A scalar point specified on this entry does not need to be defined on an SPOINT entry.
5.Scalar damper elements are ignored in heat transfer analysis.