HyperWorks Solvers

DCONADD

DCONADD

Previous topic Next topic Expand/collapse all hidden text  

DCONADD

Previous topic Next topic JavaScript is required for expanding text JavaScript is required for the print function  

Bulk Data Entry

DCONADD – Design Constraint Addition

Description

Creates a combination of several DCONSTR sets that can be referenced by a subcase.

Format

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

DCONADD

DCID

DC1

DC2

DC3

DC4

DC5

DC6

DC7

 

 

DC8

etc.

 

 

 

 

 

 

 

hmtoggle_plus1Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

DCONADD

101

10

20

30

 

 

 

 

 

Field

Contents

DCID

DCONADD identification number. Must be unique with respect to all Dci (DCONSTR IDs).

(Integer > 0)

DCi

DCONSTR identification number. Must be unique.

(Integer > 0)

Comments

1.The DCONADD entry is selected by a DESSUB or DESGLB in the Subcase Information section.
2.This card is represented as an optimizationconstraint in HyperMesh.

See Also:

Bulk Data Section

Guidelines for Bulk Data Entries

Bulk Data Entries by Function

The Input File