Description

Specifies damp shell elements for a fluid volume. ELIST entries are referenced by the MFLUID entry.

Format

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

ELIST

LID

EID1

EID2

EID3

EID4

EID5

EID6

EID7

 

 

EID8

EID9

EID10

- etc -

 

 

 

 

 

hmtoggle_plus1Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

ELIST

25

47

22

THRU

35

-56

-57

 

 

Field

Contents

LID

List of identification number.

No default (Integer > 0)

EID

Element identification number of CQUAD4, CTRIA3, CQUADR, and CTRIAR elements that are damp in the fluid volume.

No default (Integer ≠ 0 or "THRU")

Comments

1.By default, for elements only damp on one side (see WSURF1 on MFLUID entry), the damp side of an element is on the same side of the element’s normal. But a negative EIDi indicates that the fluid is opposite to the normal. If there are negative EIDi’s specified in a "THRU" range, then both EIDi’s in the range must be negative.
2.Alternatively, the SURF and SET entries may be used to define damp elements but the SURF and SET entries may not be combined in the single with ELIST entries to define damp elements. For example, if any MFLUID references a missing ELIST,25, then the program will not search for a SET,25 if a ELIST card exists in the deck.
3.ELIST is an alternative to SET and SURF, but ELIST is intended only to provide compatibility with Nastran decks. It is recommended to use SURF/SET instead of ELIST. Additionally,
The SURF and SET entries may not be combined with ELIST entries to define damp elements.
ELIST entries are internally converted to SET entries. If ELIST is referenced on a minimum of one MFLUID entry, then all MFLUID entries in a model must reference ELIST entries. In such cases, if an MFLUID entry references a particular Set Identification Number (<SID>) to define WSURF1/WSURF2 fields without a corresponding ELIST,<SID> in the model, then OptiStruct will not search for a SET/SURF,<SID>.
4.ELIST entries are internally converted to SET entries. The continuation is optional.