HyperWorks Solvers

/FAIL/ENERGY

/FAIL/ENERGY

Previous topic Next topic Expand/collapse all hidden text  

/FAIL/ENERGY

Previous topic Next topic JavaScript is required for expanding text JavaScript is required for the print function  

Block Format Keyword

/FAIL/ENERGY - Specific Energy Failure Model

Description

Describes a specific energy failure model.

Format

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

/FAIL/ENERGY/mat_ID/unit_ID

E1

E2

fct_ID

 

 

 

 

 

Optional line:

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

fail_ID

 

 

 

 

 


hmtoggle_plus1Flag Definition

Field

Contents

SI Unit Example

mat_ID

Material identifier

(Integer, maximum 10 digits)

 

unit_ID

Optional unit identifier

(Integer, maximum 10 digits)

 

E1

Maximum specific energy (Comment 2)

Default = 130  (Real)

fail_energy

E2

Failure specific energy (Comment 2)

Default = 230  (Real)

fail_energy

fct_ID

Function identifer for . It's function of specific energy E1 and E2 scaling factor vs. strain rate.

(Integer)

 

fail_ID

(Optional) Failure criteria identifier (Comment 3)

(Integer, maximum 10 digits)

 

hmtoggle_plus1Example (Metal)

In this example, using fct_ID different specific energy (E1 and E2) actually used by computation according to different test strain rate.

#RADIOSS STARTER

#---1----|----2----|----3----|----4----|----5----|----6----|----7----|----8----|----9----|---10----|

/UNIT/1

unit for mat

#              MUNIT               LUNIT               TUNIT

                  Mg                  mm                   s

#---1----|----2----|----3----|----4----|----5----|----6----|----7----|----8----|----9----|---10----|

/MAT/PLAS_TAB/1/1

Metal

#              RHO_I

         2.788714E-9

#                  E                  NU           Eps_p_max               Eps_t               Eps_m

               68000                  .3                   0                   0                   0

#  N_funct  F_smooth              C_hard               F_cut               Eps_f

         1         0                   0                   0                   0

#  fct_IDp              Fscale   fct_IDE                EInf                  CE

         0                   1         0                   0                   0

#  fct_ID1   fct_ID2   fct_ID3   fct_ID4    fct_ID5

         2

#           Fscale_1            Fscale_2            Fscale_3            Fscale_4            Fscale_5

                   0

#          Eps_dot_1           Eps_dot_2           Eps_dot_3           Eps_dot_4           Eps_dot_5

                   0

#---1----|----2----|----3----|----4----|----5----|----6----|----7----|----8----|----9----|---10----|

/FAIL/ENERGY/1/1

#                 E1                  E2    fct_ID

                 0.3                0.34        18

#---1----|----2----|----3----|----4----|----5----|----6----|----7----|----8----|----9----|---10----|

/FUNCT/18

scale factor for specific energy E1 and E2

#        strain rate        scale factor

#                  X                   Y

                   0                   1

                  50                 0.5

               10000                 0.5

#---1----|----2----|----3----|----4----|----5----|----6----|----7----|----8----|----9----|---10----|

/FUNCT/2

True Stress-True plastic strain

#                  X                   Y

                   0                 124

                 .01                 150

                 .02                 165

                 .04                 184

                 .06                 196

                 .08                 203

                  .1                 206

                 .12                 210

                 .14                 213

                 .16                 217

                 .18                 220

                  .5                 240

                1000                 240

#---1----|----2----|----3----|----4----|----5----|----6----|----7----|----8----|----9----|---10----|

#enddata

#---1----|----2----|----3----|----4----|----5----|----6----|----7----|----8----|----9----|---10----|

hmtoggle_plus1Comments
1.The element is deleted, if D= 1 for one integration point.
2.The specific energy is the current internal energy of the element divided by the current element volume. Internal energy (IE) could be observed in time history plot.

clip0007

Specific energy model failure.

3.The fail_ID is used with /STATE/BRICK/FAIL and /INIBRI/FAIL. There is no default value. If the line is blank, no value will be output for failure model variables in the /INIBRI/FAIL (written in .sta file with /STATE/BRICK/FAIL option).

See Also:

Specific Energy Failure in Theory Manual

Failure to Element/Material Compatibility