HyperWorks Solvers

/FAIL/WILKINS

/FAIL/WILKINS

Previous topic Next topic Expand/collapse all hidden text  

/FAIL/WILKINS

Previous topic Next topic JavaScript is required for expanding text JavaScript is required for the print function  

Block Format Keyword

/FAIL/WILKINS - Wilkins Failure Model

Description

Describes the Wilkins failure model.

Format

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

/FAIL/WILKINS/mat_ID/unit_ID

symbol_a_14

coeffec-B

Plim

Ifail_sh

Ifail_so

Optional line:

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

fail_ID

 

 

 

 

 

hmtoggle_plus1Flag Definition

Field

Contents

SI Unit Example

mat_ID

Material identifier

(Integer, maximum 10 digits)

 

unit_ID

Optional unit identifier

(Integer, maximum 10 digits)

 

symbol_a_14

Hydrostatic pressure exponent

(Real)

 

coeffec-B

Deviatoric coefficient

(Real)

 

Plim

Hydrostatic pressure limit

(Real)

symbol_Pa

Critical damage

(Real)

 

Ifail_sh

Shell failure flag

(Integer)

= 1: Shell is deleted, if Dp > Dƒ for one integration point or layer.

= 2: For each integration point, the stress tensor is set to zero, if Dp > Dƒ and shell is deleted, if Dp > Dƒ for all integration points or layers.

 

Ifail_so

Solid failure flag

(Integer)

= 1: Solid is deleted, if Dp > Dƒ for one integration point.

= 2: For each integration point, the deviatoric stress tensor vanishes, if Dp > Dƒ.

 

fail_ID

(Optional) Failure criteria identifier (Comment 2)

(Integer, maximum 10 digits)

 

hmtoggle_plus1Example (Metal)

#RADIOSS STARTER

#---1----|----2----|----3----|----4----|----5----|----6----|----7----|----8----|----9----|---10----|

/UNIT/1

unit for mat

#              MUNIT               LUNIT               TUNIT

                  Mg                  mm                   s

#---1----|----2----|----3----|----4----|----5----|----6----|----7----|----8----|----9----|---10----|

#-  1. MATERIALS:

#---1----|----2----|----3----|----4----|----5----|----6----|----7----|----8----|----9----|---10----|

/MAT/PLAS_JOHNS/1/1

Metal

#              RHO_I

              2.8E-9

#                  E                  NU

               60000                  .3

#                  a                   b                   n           EPS_p_max            SIG_max0

                 370                 190                  .4                   0                   0

#                  c           EPS_DOT_0       ICC   Fsmooth               F_cut               Chard

                   0                   0         0         0                   0                   0

#                  m              T_melt              rhoC_p                 T_r

                   0                   0                   0                   0

/FAIL/WILKINS/1/1

#              Alpha                Beta                Plim                  Df  Ifail_sh  Ifail_so

                 1.8                 .75                 750                 0.3         1         0

#---1----|----2----|----3----|----4----|----5----|----6----|----7----|----8----|----9----|---10----|

#enddata

#---1----|----2----|----3----|----4----|----5----|----6----|----7----|----8----|----9----|---10----|

hmtoggle_plus1Comments
1.clip0247A

Where,

Where, P is the hydro pressure

Where, S1, S2 and S3 are the deviatoric stresses.

2.The fail_ID is used with /STATE/BRICK/FAIL and /INIBRI/FAIL. There is no default value. If the line is blank, no value will be output for failure model variables in the /INIBRI/FAIL (written in .sta file with /STATE/BRICK/FAIL option).

See Also:

Wilkins Failure in Theory Manual

Failure to Element/Material Compatibility