HyperWorks Solvers

/IMPTEMP

/IMPTEMP

Previous topic Next topic Expand/collapse all hidden text  

/IMPTEMP

Previous topic Next topic JavaScript is required for expanding text JavaScript is required for the print function  

Block Format Keyword

/IMPTEMP - Imposed Temperature

Description

Defines imposed temperatures on a group of nodes.

Format

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

/IMPTEMP/imptemp_ID/unit_ID

imptemp_title

fct_IDT

sens_ID

grnd_ID

 

 

 

 

 

 

 

Ascalex

FscaleY

Tstart

Tstop

 

 

hmtoggle_plus1Flag Definition

Field

Contents

SI Unit Example

imptemp_ID

Imposed temperature block identifier

(Integer, maximum 10 digits)

 

unit_ID

Optional unit identifier

(Integer, maximum 10 digits)

 

imptemp_title

Imposed temperature block title

(Character, maximum 100 characters)

 

fct_IDT

Time function identifier

(Integer)

 

sens_ID

Sensor identifier

≠ 0: the imposed temperature is applied after sensor activation. The time function is shifted in time.

(Integer)

 

grnd_ID

Node group to which the imposed temperature is applied

(Integer)

 

Ascalex

Abscissa (time) scale factor for fct_IDT

Default = 1.0  (Real)

symbol_S_unit

Fscaley

Ordinate (temperature) scale factor for fct_IDT

Default = 1.0  (Real)

fail_tab_temp

Tstart

Start time

(Real)

symbol_S_unit

Tstop

Stop time

Default = 1030  (Real)

symbol_S_unit

See Also:

Implicit Features and Compatibility Information

Example 53 - Thermal Analysis