HyperWorks Solvers

LIFE

LIFE

Previous topic Next topic No expanding text in this topic  

LIFE

Previous topic Next topic JavaScript is required for expanding text JavaScript is required for the print function  

I/O Options and Subcase Information Entry

LIFE – Output Request

Description

The LIFE command can be used in the I/O Options or Subcase Information sections to request output of fatigue life results for all fatigue subcases or individual fatigue subcases, respectively.

Format

LIFE (format_list) = option

Argument

Options

Description

format

<H3D, OPTI, blank>

Default = blank

H3D:

Results are output in Hyper3D format (.h3d file).

OPTI:

Results are output in OptiStruct results format (.fat file).

blank:

Results are output in all active formats for which the result is available.

 

option

<YES, ALL, NO, NONE, SID>

Default = ALL

YES, ALL, blank:

Results are output for all elements.

NO, NONE:

Results are not output.

SID:

If a set ID is given, results are output only for elements listed in that set.

Comments

1.When a LIFE command is not present, fatigue life results are not output.
2.Multiple formats are allowed on the same entry; these should be comma separated. If a format is not specified, this output control applies to all formats defined by the OUTPUT command, for which the result is available. See Results Output by OptiStruct for information on which results are available in which formats.
3.Multiple instances of this card are allowed; if instances are conflicting, the last instance dominates.

See Also:

I/O Options Section

I/O Options by Function

The Input File