MATT9 – Solid Element Anisotropic Material Temperature Dependence

Description

Specifies temperature-dependent material properties on MAT9 entry fields via TABLEMk entries.

Format

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

MATT9

MID

T(G11)

T(G12)

T(G13)

T(G14)

T(G15)

T(G16)

T(G22)

 

 

T(G23)

T(G24)

T(G25)

T(G26)

T(G33)

T(G34)

T(G35)

T(G36)

 

 

T(G44)

T(G45)

T(G46)

T(G55)

T(G56)

T(G66)

T(RHO)

T(A1)

 

 

T(A2)

T(A3)

T(A4)

T(A5)

T(A6)

 

T(GE)

 

 

hmtoggle_plus1Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

MATT9

17

32

 

 

18

 

 

17

 

 

 

 

 

12

 

 

 

 

 

 

 

 

 

5

 

 

10

 

 

Field

Contents

MID

Material property identification number that matches the identification number on a MAT9 entry.

(Integer > 0)

T(Gij)

Identification number of a TABLEMk entry for the terms in the material property matrix.

(Integer > 0 or blank)

T(RHO)

Identification number of a TABLEMk entry for the mass density.

(Integer > 0 or blank)

T(Ai)

Identification number of a TABLEMk entry for the thermal expansion coefficients.

(Integer > 0 or blank)

T(GE)

Identification number of a TABLEMk entry for the damping coefficient.

(Integer > 0 or blank)

Comments

1.Fields 3, 4, and so on of this entry correspond, field-by-field, to fields 3, 4, and so on of the MAT9 entry referenced in field 2. The value recorded in a particular field of the MAT9 entry is replaced or modified by the table referenced in the corresponding field of this entry. In the example shown, G11 is modified by TABLEMj 32; G14 is modified by TABLEMj 18, and so on. If the fields are zero or blank, there is no temperature dependence of the field on the MAT9 entry.
2.The MATT9 entries may refer to blank entries on the respective MAT9 card. In which case, they will be applied to default values of respective parameters.
3.The continuation entries are optional.
4.The TEMPERATURE subcase information entry (with type = MATERIAL) is required to activate temperature-dependent material behavior and to define the temperature field (option = SID of TEMP, TEMPD or the SUBCASE ID of a thermal analysis subcase).
5.With TABLEM1, the respective field on MAT9 will be replaced by the table data on MATT9. With TABLEM2/3/4, the respective field of MAT9 will be modified by the table data.
6.This card is represented as a material in HyperMesh.

See Also:

Bulk Data Section

Guidelines for Bulk Data Entries