HyperWorks Solvers

MBFRC

MBFRC

Previous topic Next topic Expand/collapse all hidden text  

MBFRC

Previous topic Next topic JavaScript is required for expanding text JavaScript is required for the print function  

Bulk Data Entry

MBFRC – Force for Multi-body Solution Sequence

Description

Defines a constant force at a grid point by specifying a vector.

Format

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

MBFRC

SID

G1

CID

F

G3/N1

N2

N3

G2

 

 

 

 

G4

 

 

 

 

 

 

hmtoggle_plus1Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

MBFRC

3

345

 

100.0

0.0

1.0

0.0

 

 

 

 

 

201

 

 

 

 

 

 

Field

Contents

SID

Load set identification number.

No default (Integer > 0)

G1

Grid point identification number where the action force is applied.

No default (Integer > 0)

CID

Coordinate system identification number. Blank or 0 infer the basic coordinate system.

Default = 0 (Integer > 0 or blank)

F

Force magnitude.

No default (Real)

G3

Grid point identification number to optionally supply N1, N2, N3 in conjunction with G1.

(Integer > 0)

N1, N2, N3

Defines the direction of the force vector. At least one of the vector components must be non-zero.

Default = 0.0 (Real)

G2

Grid point identification number where the reaction force is applied. If blank, the force is an action-only force.

Default = blank (Integer > 0 or blank)

G4

Grid point identification number whose parent body hosts the coordinate system with respect to which the force is defined. The force vector changes direction with the orientation of the body.

If not specified, the force is defined with respect to the ground body (that is the basic coordinate systems).

Default = blank (Integer > 0 or blank)

Comments

1. This card is represented as a force load in HyperMesh.

See Also:

Bulk Data Section

Guidelines for Bulk Data Entries

The Input File