HyperWorks Solvers

MBMNTC

MBMNTC

Previous topic Next topic Expand/collapse all hidden text  

MBMNTC

Previous topic Next topic JavaScript is required for expanding text JavaScript is required for the print function  

Bulk Data Entry

MBMNTC – Curve moment for Multi-body Solution Sequence

Description

Defines a curve moment at a grid point by specifying a vector.

Format

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

MBMNTC

SID

G1

CID

CVID

G3/N1

N2

N3

G2

 

 

INT

EID

 

 

 

 

 

 

 

hmtoggle_plus1Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

MBMNTC

3

345

 

4

0.0

1.0

0.0

 

 

 

AKIMA

42

 

 

 

 

 

 

 

Field

Contents

SID

Load set identification number.

No default (Integer > 0)

G1

Grid point identification number where the action force is applied.

No default (Integer > 0)

CID

Coordinate system identification number. Blank or 0 infer the basic coordinate system.

Default = 0 (Integer > 0, or blank)

CVID

Set identification number of the MBCRV entry that gives the load vs. independent variable measured in the coordinate system defined by CID.

(Integer > 0)

G3

Grid point identification number to optionally supply N1, N2, N3 in conjunction with G1.

(Integer > 0)

N1,N2,N3

Defines the direction of the force vector. At least one of the vector components must be non-zero.

Default = 0.0 (Real)

G2

Grid point identification number where the reaction force is applied. If blank or zero, then the force is an action-only force.

Default = 0 (Integer > 0)

INT

Interpolation type

Default = AKIMA (Character: LINEAR, CUBIC, or AKIMA)

EID

Set identification number of the MBVAR for the independent variable expression.

Default = TIME (Integer > 0 or blank)

Comments

1.This card is represented as a moment load in HyperMesh.

See Also:

Bulk Data Section

Guidelines for Bulk Data Entries

Bulk Data Entries by Function

The Input File