MBSEQ – Multi-body System Simulation Sequence

Description

Defines the simulation sequence for the multi-body solver.

Format

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

MBSEQ

ID

SID1

SID2

SID3

 

 

 

hmtoggle_plus1Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

MBSEQ

9

99

12

43

 

 

 

 

 

Field

Contents

ID

Unique identification number.

(Integer > 0)

SID1, SID2, …

IDs of the simulation sequence.

(Integer > 0) (Valid IDs are: MBSIM, MBLIN, MBSIMP, MBACT, or  MBDEACT)

Comments

1.Every time an MBSIM card is encountered, a simulation is performed on the multi-body model. The initial condition for the next MBSIM will be the ending condition of the current simulation.
2.This card is represented as a loadcollector in HyperMesh.

See Also:

Bulk Data Section

Guidelines for Bulk Data Entries

The Input File