Bulk Data Entry
MBSFRCC – Curve Scalar Load for Multi-body Solution Sequence
Description
Defines a curve scalar load on two grid points.
Format
(1) |
(2) |
(3) |
(4) |
(5) |
(6) |
(7) |
(8) |
(9) |
(10) |
MBSFRCC |
SID |
G1 |
G2 |
CVID |
INT |
EID |
|
|
|
|
Field |
Contents |
SID |
Load set identification number. No default (Integer > 0) |
G1 |
Grid point identification number. No default (Integer > 0) |
G2 |
Grid point identification number. No default (Integer > 0) |
CVID |
Set identification number of the MBCRV entry that gives the load vs. independent variable measured in the coordinate system defined by CID. (Integer > 0) |
INT |
Interpolation type Default = AKIMA (Character: LINEAR, CUBIC, or AKIMA) |
EID |
Set identification number of the MBVAR for the independent variable expression. Default = TIME (Integer > 0 or blank) |
1. | MBSFRCC applies a translational action-reaction force along the line of action defined by the line segment connecting G1 and G2. |
2. | The action force is applied to G1 and the reaction force is applied to G2. |
3. | Tensile force is positive. |
See Also: