Subcase Information Entry

MBSIM – Multi-Body Simulation Selection

Description

The MBSIM command can be used in the Subcase Information section to select a multi-body simulation definition to be applied in a multi-body problem.

Format

MBSIM = option

Argument

Options

Description

option

< SID >

No default

SID:

Set identification of MBSEQ, MBSIM, or MBLIN bulk data entries.

Comments

1.Only one MBSIM entry can be present for each subcase.
2.This subcase information entry is only valid when it appears in a multi-body subcase.
3.MBSIM can be used to select only one bulk data entry. MBSEQ, MBSIM, and MBLIN must have unique IDs.