Bulk Data Entry
MBSMNT – Scalar Moment for Multi-body Solution Sequence
Description
Defines a constant scalar moment on two gird points along the specified vector.
Format
(1) |
(2) |
(3) |
(4) |
(5) |
(6) |
(7) |
(8) |
(9) |
(10) |
MBSMNT |
SID |
G1 |
G2 |
T |
G3/Vx |
Vy |
Vz |
|
|
|
Field |
Contents |
SID |
Load set identification number. No default (Integer > 0) |
G1 |
Grid point identification number. No default (Integer > 0) |
G2 |
Grid point identification number. No default (Integer > 0) |
T |
Value of moment. (Real) |
G3 |
Grid point identification number to optionally supply Vx, Vy, and Vz in conjunction with G1. (Integer > 0) |
Vx |
X component of vector V. |
Vy |
Y component of vector V. |
Vz |
Z component of vector V. |
1. | MBSMNT applies a scalar action-reaction moment on G1 and G2 along the vector defined by Vx, Vy, and Vz. |
2. | The action moment is applied to G1 and the reaction moment is applied to G2. |
3. | Right hand rule defines the positive moment. |
See Also: