Model Element |
|
Description |
|
The Messaging element allows you to control how MotionSolve generates messages. |
|
Format |
|
<Messaging> log_option = { "Overwrite" | "ScreenOnly" | "Append" } usrsub_param_string = "USER( [[par_1 [, ...][,par_n]] )" usrsub_dll_name = valid_path_name usrsub_fnc_name = "MESSAGE_SUB" </MESSAGING> |
|
Attributes |
|
log_option |
Select from Overwrite, ScreenOnly, and Append. Overwrite - specifies whether the LOG file should be overwritten. ScreenOnly - the messages should be sent only to the computer screen. Append - whether the log file should be appended to. |
usrsub_param_string |
The list of parameters that are passed from the data file to the user written subroutine, MESSAGE_SUB. |
usrsub_dll_name |
Specifies the path and name of the DLL or shared library containing user subroutine. MotionSolve uses this information to load the user subroutine in the DLL at run time. |
usrsub_fnc_name |
Specifies the path and name of the DLL or shared library containing user subroutine. MotionSolve uses this information to load the user subroutine in the DLL at run time. |