HyperWorks Solvers

NLMON

NLMON

Previous topic Next topic No expanding text in this topic  

NLMON

Previous topic Next topic JavaScript is required for expanding text JavaScript is required for the print function  

Subcase Information Entry

NLMON – Nonlinear Analysis Monitoring

Description

This NLMON subcase information entry can be used to activate Nonlinear Monitoring for a subcase by referencing a corresponding NLMON Bulk Data Entry.

Format

NLMON = option

Argument

Options

Description

option

< ID >

No default

ID: Set identification number of an NLMON Bulk Data Entry.

Comments

1.NLMON is currently supported for Small and Large Displacement Nonlinear static and Large Displacement Nonlinear Transient analysis only. By extension to Nonlinear Transient Analysis, it is also supported for Structural Fluid-Structure Interaction (FSI).
2.In addition to the <filename>.h3d file generated at the end of analysis, for subcases with NLMON turned on a second result file named filename_nl.h3d is written during runtime, and this file can be used to monitor progress of the solution.
3.For subcases with NLMON turned on, extra diagnostic information on iteration and convergence will be printed in the .out file.

See Also:

Subcase Information Section

The Input File