NLOUT – Controls the incremental result output for Small Displacement Nonlinear Analysis and Large Displacement Analysis

Description

The NLOUT bulk data entry defines incremental result output parameters for small displacement nonlinear analysis and large displacement analysis.

Format

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

NLOUT

ID

PARAM1

VALUE1

PARAM2

VALUE2

 

 

 

 

hmtoggle_plus1Example

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

NLOUT

3

NINT

20

SVNONCNV

YES

 

 

 

 

Field

Contents

ID

Each NLOUT Bulk Data Entry should have a unique ID.

No default (Integer > 0)

NINT

Number of intervals specified to output intermediate results. See comment 2.

Default = 10  (Integer > 0)

SVNONCNV

Flag to output the non-convergent solution, if nonlinear iterations does not converge.

Default = YES  (YES, NO, or blank)

Comments

1.The NLOUT Bulk Data Entry is selected by the Subcase Information Entry NLOUT=ID. The NLOUT Subcase Entry can be specified in Nonlinear Small Displacement Quasi-Static Analysis, Large Displacement Quasi-Static Analysis, and Nonlinear Direct Transient Analysis.
2.If the load increment from previous load level to the current load level is greater than 1/NINT, intermediate result corresponding to current load level is saved for output; otherwise, it is not saved. Note that this parameter has no control on the adaptive load size selection.
3.The following results are currently supported for NLOUT in h3d/OPTI format: DISPLACEMENT, STRESS, STRAIN, ELFORCE, CONTF, and SPCFORCE (only LGDISP)), and OLOAD.

See Also:

Bulk Data Section

Guidelines for Bulk Data Entries

Bulk Data Entries by Function