HyperWorks Solvers

PARAM, FASTCONT

PARAM, FASTCONT

Previous topic Next topic No expanding text in this topic  

PARAM, FASTCONT

Previous topic Next topic JavaScript is required for expanding text JavaScript is required for the print function  

Parameter

Values

Description

FASTCONT

<YES, NO>

Default = NO

Controls the activation of CONTACT/CGAP(G)-based Fast Contact. If this parameter does not exist in the input deck (default), Linear Gap Analysis is not activated.

YES – CONTACT/CGAP(G)-based Fast Contact Analysis is activated.

NO – CONTACT/CGAP(G)-based Fast Contact Analysis is not activated.

Note

1.In models containing contact, CONTACT/CGAP(G)-based Fast Contact is only supported for CONTACT=SLIDE.
2.Models containing surfaces with user-created CGAP elements are also supported.
3.MPC-based Fast Contact Analysis is available via PARAM,CDITER, SUPORT, SPOINT, and SPC entries are required for such model. PARAM,FASTCONT should not be used for MPC-based Fast Contact.