HyperWorks Solvers

/PARITH

/PARITH

Previous topic Next topic No expanding text in this topic  

/PARITH

Previous topic Next topic JavaScript is required for expanding text JavaScript is required for the print function  

Engine Keyword

/PARITH - Parallel Arithmetic Flag

Description

Turns the parallel arithmetic ON/OFF.

Format

/PARITH/Keyword2

Data

Description

Keyword2

ON or OFF

Comments

1.The default value is defined by RADIOSS Starter (Iparith flag of RADIOSS Starter /ANALY) for the first Engine run or by the value of the previous run.
2.If this option is ON, the same numerical results will be obtained whatever the number of processors. This result is not guaranteed in case of incompatible kinematic conditions in the model.
3.The previous run must be PARITH =ON in order to use PARITH =ON for the current run in case of multiple RADIOSS Engine runs.
4.PARITH/ON is not available for implicit analysis.

See Also:

Parallelism in FAQ